Download Inhoudsopgave Inhoud Print deze pagina

Disposal Of Accessories; Technical Data; Operation Characteristic Values - Dräger Scio Four Aanvullende Handleiding

Inhoudsopgave

Advertenties

www.draeger.com. Use the search function with the keyword
"WEEE" to find the relevant information. If access to Dräger's web-
site is not possible, contact the local Dräger Organization.

Disposal of accessories

When disposing of the following accessories, observe the hospital
hygiene regulations. Observe the instructions for use of the
respective accessories (if provided):

Technical data

Operation characteristic values

Dimensions with water trap
Height
Width
Depth
Weight
Scio Four
Scio Four Oxi
Scio Four plus
Scio Four Oxi plus
Mode of operation
Device noise emissions
Cooling
Dimensions of the external power supply
Height
Width
Depth
Mains power supply
Rated current
Inrush current
Power consumption
Housing leakage current
Protection classes
Device
Electric shock protection
Penetration of liquids
Penetration of liquids (power supply)
Classification according to European Medical
Device Regulation
UMDNS Code Universal Medical Device
Nomenclature System - nomenclature system for
medical devices
Use of latex
Supplement Scio Four modules
Filter, HME, HMEF
Water trap
Sample line
Sample gas return kit
Scavenging hose
115 mm (4.8 in)
190 mm (7.5 in)
270 mm (10.5 in)
2.9 kg + 0.1 kg (6.4 lbs + 0.22 lbs)
3.2 kg + 0.1 kg (7.0 lbs + 0.22 lbs)
2.9 kg + 0.1 kg (6.4 lbs + 0.22 lbs)
3.2 kg + 0.1 kg (7.0 lbs + 0.22 lbs)
Continuous
45 db(A)
Fan, temperature-regulated
33 mm (1.3 in)
68 mm (2.7 in)
109 mm (4.3 in)
100 to 240 V~ 50/60 Hz
1.5 A (1.5 A - 0.7 A)
40 A, cold start at 264 V~ input
60 W
300 µA (per UL 60601-1:2003)
500 µA (per UL 60601-1:1988 incl. corrections)
The power supply supplies the Scio Four module with 12 VDC.
The metal collar of the 12 VDC supply connector on the back of the Scio four
establishes a functional ground connection of the Scio housing to earth.
Class I
Type BF
Scio Four modules are intended to connect to a patient by means of a WaterLock2
water trap, a sample gas line and patient connectors.
These parts and accessories are subjected to the requirements for a 'type BF
applied part' (IEC 60601-1 & ISO 80601-2-55).
IP21
IP22
IIb
17-445
No latex (natural rubber) is used in parts with indirect or direct contact to patients
or operators.