Par.
Parameter
Nr.
100
Setpoint source
101
Control source
11. AI1 analog input
110
AI1 scaling
111
AI1 offset
[mV] 8464 2110
112
AI1 operating mode
113
AI1 voltage offset
114
AI1 speed offset
[1/min] 8467 2113
115
Filter setpoint
[ms] 8468 2114
12. Analog inputs (optional)
120
AI2 operating mode (opt.)
13. Speed ramps 1
130
t11 ramp up CW
131
t11 ramp down CW
132
t11 ramp up CCW
133
t11 ramp down CCW
®
MOVIDRIVE
Veldbus-protocol
Index
Eenheid/index
Dec Hex
Afk. Gr. Om.
8461 210D
0
0
8462 210E
0
0
8463 210F
0
-3
V
21
-3
8465 2111
0
0
[V] 8466 2112
V
21
-3
1/s
11
66
s
4
-6
8469 2115
0
0
[s] 8470 2116
s
4
-3
[s] 8471 2117
s
4
-3
[s] 8472 2118
s
4
-3
[s] 8473 2119
s
4
-3
Parameterlijst gesorteerd
Toegang Standaard Betekenis / bereik
N/R/RW
0
0 = BIPOL./FIXED SETPOINT
1 = UNIPOL./FIXED SETPOINT
2 = RS485
3 = FIELDBUS
4 = MOTORPOTENTIOM.
5 = MOTORPOT+ANALOG1
6 = FIXEDSET+ANALOG1
7 = FIXEDSET*ANALOG1
8 = MASTER SBus
9 = MASTER RS485
10 = SBus
N/R/RW
0
0 = TERMINALS
1 = RS485
2 = FIELDBUS
3 = SBus
N/RW
1000
-10000...-0, Step 10
0...10000, Step 10
N/RW
0
-500...-0, Step 1
0...500, Step 1
N/RW
1
0 = Reference 3000 1/min
1 = Reference N-MAX
2 = U-Off., N-MAX
3 = N-Off., N-MAX
4 = Expert characteristic curve
5 = N-MAX, 0-20mA
6 = N-MAX, 4-20mA
N/RW
0
-10000...-0, Step 10
0...10000, Step 10
N/RW
0
-5000000...-0, Step 200
0...5000000, Step 200
N/RW
5000
0...1000, Step 1000
1000...20000, Step 10
20000...50000, Step 100
50000...100000, Step 1000
N/R/RW
0
0 = NO FUNCTION
1 = 0..+/-10V+Setpoint1
2 = 0..10V I limit
3 = ACTUAL VALUE
CONTROLLER
N/RW
2000
0...1000, Step 10
1000...10000, Step 100
10000...100000, Step 1000
100000...2000000, Step 10000
N/RW
2000
0...1000, Step 10
1000...10000, Step 100
10000...100000, Step 1000
100000...2000000, Step 10000
N/RW
2000
0...1000, Step 10
1000...10000, Step 100
10000...100000, Step 1000
100000...2000000, Step 10000
N/RW
2000
0...1000, Step 10
1000...10000, Step 100
10000...100000, Step 1000
100000...2000000, Step 10000
op parameternummer
8
67