96
ACS550-U1
Parameter
9902
1 =
APPLICATIEMACRO
ABB STAND
9904
3 =
MOTOR CTRL
MODE
1001
1
2 =
EXT
OPDRACHTEN
1002
2
0 =
EXT
OPDRACHTEN
GESELEC
1003
3 =
DRAAIRICHTING
1102
1/
2 0 =
KEUZE EXT
EXT
1103
1
1 =
KEUZE REF
1106
2
2 =
KEUZE REF
1201
9 =
KEUZE CNST TOER
1304
2
0.0%
MINIMUM AI
1401
1 1 =
RELAISUITGANG
1402
2 2 =
RELAISUITGANG
BEDRIJF
1403
3 3 =
RELAISUITGANG
1501
1
103 = 0103
AN UITG
INHOUD
UITGANGSFREQ
1507
2
104 =
AN UITG
INHOUD
STROOM
1510
2 0.0 mA
MINIMUM AN UITG
1601
0 =
STARTVRIJGAVE
GESELEC
2201
/
1/
5 =
KEUZE ACC
DEC
2
3201
1
103 = 0103
BEWAK
PARAM
UITGANGSFREQ
3401
1
103 = 0103
SIGNAAL
PARAM
UITGANGSFREQ
4001
1.0
VERSTERKING
4002
60.0 s
INTEGRATIE TIJD
4101
1.0
VERSTERKING
4102
60.0 s
INTEGRATIE TIJD
8123
0 =
PFC VRIJGAVE
GESELEC
Applicatiemacro's
ABB
3-draads
Standaard
2 =
3 =
3-
DRAADS
ALTERNEREN
D
1 =
1 =
SCALAR
TOERENTAL
TOERENTAL
1,2
4 =
1
,2
,3 9 =
DI
DI
P
P
0 =
0 =
NIET
NIET
GESELEC
GESELEC
3 =
3 =
VERZOEK
VERZOEK
1
0 =
1
0 =
EXT
EXT
1
1 =
1
1 =
AI
AI
2
2 =
2
2 =
AI
AI
3,4
10 =
4,5 9 =
DI
DI
0.0%
0.0%
1 =
1 =
GEREED
GEREED
2 =
2 =
IN
IN
BEDRIJF
BEDRIJF
(-1) 3 =
(-1) 3 =
FOUT
FOUT
102 = 0102
102 = 0102
TOERENTAL
TOERENTAL
104 =
104 =
STROOM
STROOM
0.0 mA
0.0 mA
0 =
6 =
NIET
NIET
GESELEC
5
0 =
5 =
DI
NIET
GESELEC
102 = 0102
102 = 0102
TOERENTAL
TOERENTAL
102 = 0102
102 = 0102
TOERENTAL
TOERENTAL
1.0
1.0
60.0 s
60.0 s
1.0
1.0
60.0 s
60.0 s
0 =
0 =
NIET
NIET
GESELEC
GESELEC
Motor-
Alter-
potentio-
Hand-auto
nerend
meter
4 =
5 =
MOTORPOT
HAND
1 =
1 =
TOERENTAL
TOERENTAL
1
,2
2 =
1,2
2 =
DI
F
R
DI
0 =
7 =
NIET
NIET
GESELEC
3 =
3 =
VERZOEK
VERZOEK
1
0 =
1
3 =
EXT
EXT
1
12 =
1 =
AI
3
,4
(
)
DI
U
D
NC
2
2 =
2
2 =
AI
AI
3,4
5 =
5
0 =
DI
DI
GESELEC
0.0%
20.0%
1 =
1 =
GEREED
GEREED
2 =
2 =
IN
IN
BEDRIJF
BEDRIJF
(-1) 3 =
(-1) 3 =
FOUT
FOUT
102 = 0102
102 = 0102
TOERENTAL
TOERENTAL
104 =
104 =
STROOM
STROOM
0.0 mA
0.0 mA
6
6 =
6
4 =
DI
DI
5
0 =
0 =
DI
NIET
GESELEC
GESELEC
102 = 0102
102 = 0102
TOERENTAL
TOERENTAL
102 = 0102
102 = 0102
TOERENTAL
TOERENTAL
1.0
1.0
60.0 s
60.0 s
1.0
1.0
60.0 s
60.0 s
0 =
0 =
NIET
NIET
GESELEC
GESELEC
ACS550-01/U1 gebruikershandleiding
PID-
PFC-
regeling
besturing
6 =
7 =
/
-
AUTO
PID
PFC BESTUR
REGELING
1 =
3 =
SCALAR
TOERENTAL
1,2
1 =
1
1 =
DI
DI
DI
6,5
6 =
6
6 =
DI
DI
DI
1 =
1 =
VERZOEK
VOORUIT
VOORUIT
3
2 =
2
3 =
DI
DI
1
1 =
1
1 =
AI
AI
2
19 =
1
19 =
AI
PID
UIT
9 =
3,4
0 =
NIET
DI
GESELEC
20.0%
20.0%
1 =
2 =
GEREED
GEREED
BEDRIJF
2 =
3 =
IN
IN
FOUT
BEDRIJF
(-1) 3 =
(-1) 31 =
FOUT
FOUT
102 = 0102
103 = 0103
TOERENTAL
UITGANGSFREQ
104 =
130 =
1
STROOM
PID
WERKELIJK
0.0 mA
4.0 mA
4
5 =
5
2 =
DI
DI
0 =
0 =
NIET
NIET
GESELEC
GESELEC
102 = 0102
103 = 0103
TOERENTAL
UITGANGSFREQ
102 = 0102
103 = 0103
TOERENTAL
UITGANGSFREQ
1.0
2.5
60.0 s
3.0 s
1.0
2.5
60.0 s
3.0 s
0 =
1 =
NIET
NIET
GESELEC
Koppel-
regeling
8 =
KOPPEL REG
2 =
KOPPEL
1
2 =
1,2
DI
6
2 =
1,2
DI
3 =
VERZOEK
3
3 =
3
DI
DI
1
1 =
1
AI
AI
1
2 =
2
PID
UIT
AI
4 =
4
NIET
DI
20.0%
1 =
IN
GEREED
(-1) 2 =
IN
BEDRIJF
3 =
(-1)
PFC
FOUT
102 = 0102
TOERENTAL
104 =
STROOM
0.0 mA
2
6 =
6
DI
DI
5 =
5
NIET
DI
102 = 0102
TOERENTAL
102 = 0102
TOERENTAL
1.0
60.0 s
1.0
60.0 s
0 =
ACTIEF
NIET
GESELEC