Installer
Technical assistance
Reset factory values
Reset
Main Menu
User Menu
mode
MAIN
VP
(Main Page)
Pressure/level
C1
Menu Selection
P1 phase current
C2
P2 phase current
PO1
Power P1
PO2
Power P2
VE
HW and SW information
SN
Serial
Identifying colours
Access by name with a drop-down menu
The selection of the various menus is accessed by name. The menu selection is accessed from the main menu by pressing "+" or "–".
The names of the menus that can be accessed appear on the menu selection page and one of the menus is highlighted by a bar (see
Figure 58). Shift the highlighting bar using the "+" and "-" keys to select the menu you want and enter it by pressing SET.
The menus displayed are MAIN, USER, MONITOR, followed by a fourth item, EXTENDED MENU; this item allows the number of
menus displayed to be extended. When EXTENDED MENU is selected a pop-up appears asking you to type in an access key
(PASSWORD). The access key (PASSWORD) coincides with the combination of keys used for direct access and allows the extended
display of the menus from the menu corresponding to the access key to all those with a lower priority.
The order of the menus is: User, Monitor, Setpoint, Installer, Technical Assistance.
When an access key is selected, the menus released remain available for 15 minutes or until they are disabled manually by means of
the item "Hide forward menus" which appears on the menu selection when using an access key.
ENGLISH
Table 15: Access to the menus
Monitor Menu
Setpoint Menu
set-minus
mode-set
FF
SP
Fault & Warning Log
Setpoint pressure
CT
RP
Contrast
Pressure differential
LA
HC
Language
P2 starting level
HS
HB
System on hours
P1 starting level
H1
HA
P1 on hours
Stopping level
H2
P2 on hours
Legend
Notes on the parameters
Only in pressure boosting with active pressure sensor
Only if a pressure or depth sensor is used
Only in kiwa mode
Only in filling or drainage with a depth sensor
Read-only parameters.
Table 16: Menu structure
Figure 58: Selection of the drop-down menus
101
5 Sec
5 Sec
2 sec after switching on appliance
2 Sec
Installer Menu
Tech. Assist. Menu
mode-set-minus
RC
Rated current:
Water lack blockage time
MF
Operating mode
MC
Control devices
GS
Protection devices
PR
Type of sensor used
MS
Measuring system
SO
Dry running factor
MP
Minimum pressure threshold
OD
Expansion vessel size
EP
Exclude pump
mode-set-plus
TB
T1
Low pressure delay
T2
Switch-off delay
ET
Exchange mode
AL
Anti-leakage
AB
anti-blocking drainage
TH
Tank height
ML
Maximum level alarm
LL
Minimum level alarm
PS
Power supply system
RF
Reset fault & warning
PW
Change password