• If you need to change the value of the charging current, press the button "ENTER/START". The charging current
flashes. Change the charging current with the "INC" and "DEC" buttons. Press and hold the respective button a
little longer for fast adjustment.
Confirm the set charging current by pressing the "ENTER/START" button.
The maximum charging current depends on battery type and the number of cells. The max. charging power
per channel is 80 W.
• Press and hold the "ENTER/START" button (about 3 seconds) to start the charging process.
The charger will beep if the settings are wrong or a malfunction is detected and the corresponding informati-
on is displayed on the screen. End the warning signal with the "BATT/PROG/STOP" button, and the charger
will go back to the previous setup menu.
During the charging process, the following data may be displayed on the screen:
The battery type ("Pb" = lead-acid battery) is shown at the top left, the
charging current top centre and the current battery voltage top right.
Bottom left has the current battery program ("CHG" = "CHARGE"); the
elapsed charging time is in the middle and to the right the charged capacity
in mAh.
• An audible signal sounds (if this feature has not been turned off) when charging is complete.
Press the "BATT/PROG/STOP" button if you wish to abort charging.
c) Discharging the battery ("DISCHARGE")
To bring partially charged lead-acid batteries to a defined initial state, discharge them by means of this battery
program.
The maximum discharge current depends on the battery type, battery capacity and number of cells. The
max. discharge power of the charger is 80 W; this limits the max. possible discharge current in batteries with
multiple cells.
The battery program can also be utilized to measure the battery's capacity.
Proceed as follows when discharging a lead-acid battery:
• As already described in Chapter 13. a), first select the battery type "Pb BATT" from the main menu with the
buttons "INC" or "DEC" and press "ENTER/START".
• Use the "INC" or "DEC" buttons to select the battery program
"DISCHARGE".
The set battery type is shown top left on the display and the battery
program next to it on the right.
The value at the bottom left indicates the present set discharge current; the value at bottom right is the voltage or
cell count of the lead-acid battery (our example shows a 6 cell lead-acid battery (6 x 2.0V = 12.0V).
Use the "INC" or "DEC" buttons to select a different battery program; return to the main menu with the button
"BATT/PROG/STOP".