NC-foutmeldingen | Lijst met NC-foutmeldingen
Foutnummer
235-0081
235-0083
235-0085
235-0086
HEIDENHAIN | TNC7 | TNCguide | 01/2022
Beschrijving
Error message
Machineconfiguratiebestand (.mcg) %1 foutief
Cause of error
There is an error in the machine configuration.
You will find more detailed information on the error in the
additional information.
Error correction
Inform your service agency.
Error message
Fout bij inlezen van machineconfiguratiebestand (.mcg) %1
Cause of error
The machine configuration file (.mcg) cannot be imported.
You will find more detailed information on the error in the
additional information.
Error correction
- Check the configuration datum CfgPlcPath.compCfgFile.
- Inform your service agency.
Error message
Topologiefout in IOC-bestand
Cause of error
The options set in the machine configuration do not match
those in the IOC file.
You will find more detailed information on the error in the
additional information.
Error correction
- Check the options set in the machine configuration and in
the IOC file.
- Inform your service agency.
Error message
Supervisor neemt controle over via PROFINET-eindapparaat
Cause of error
Een supervisor heeft de controle over een op de besturing
aangesloten PROFINET-eindapparaat overgenomen.
De machine kan pas weer opnieuw worden ingeschakeld
wanneer de supervisor de controle weer heeft teruggegeven.
Error correction
- De supervisor instrueren de controle weer aan de besturing
terug te geven
- Fout bevestigen
- Machine inschakelen
- Meer informatie vindt u in de PROFINET-diagnose