NC-foutmeldingen | Lijst met NC-foutmeldingen
Foutnummer
303-0008
303-0009
303-000A
303-000B
HEIDENHAIN | TNC7 | TNCguide | 01/2022
Beschrijving
Error message
Datum %1 niet geconfigureerd
Cause of error
No value was entered
in the configuration datum
%1.
It is absolutely essential. The node and all child elements will
not be created.
Error correction
Check the configuration datum
Error message
Cyclische ouder-kindrelatie
Cause of error
The entities CfgOpcUaObject and CfgOpcUaPlcVar with the
following keys form a cyclic reference though their parent-
Node attributes:
%1
This is not permitted. The nodes stated and all child
elements will not be created.
Error correction
Check the respective parentNode attributes
Error message
Ongeldige namespace-URI %1
Cause of error
An invalid namespace URI was entered in the namespaceUri
attribute
in the configuration datum
%1.
The node and all child elements will not be created.
Error correction
Enter a correct namespace URI
Error message
Ongeldige oudernode: %1
Cause of error
The entity CfgOpcUaObject
%1
references an CfgOpcUaPlcVar entity as parent node.
This is not allowed. The node and all child elements will not
be created.
Error correction
Check the parentNode attribute
41
3137