Download Print deze pagina

HEIDENHAIN TNC7 Handleiding pagina 3231

Verberg thumbnails Zie ook voor TNC7:

Advertenties

NC-foutmeldingen | Lijst met NC-foutmeldingen
Foutnummer
330-00BC
330-00BD
HEIDENHAIN | TNC7 | TNCguide | 01/2022
Beschrijving
Error message
CC%2 error in cut-out channel STO.A.x (-STO.A.MC.WD=0)
ax-grp. S
Cause of error
The cutout channel test detected a fault:
The CC-specific pulse deletion for the corresponding power
modules of the spindle axis group (S) over the A channel is
defective.
Switch-off signal: STO.A.MC.WD
Switch-off signal: STO.A.x
At least one of the acknowledgment signals for this cutout
channel has the wrong condition, i.e. when
- JH inverter: At least one power module reports "readi-
ness" (RDY.x=1), although for all power modules of the axis
group S of the CC, "No readiness" (RDY.x=0) is expected.
- DRIVE-CLiQ inverter: At least on of the associated diagnos-
tic signal is "1", although "0" is expected.
Error correction
- Check the wiring (PWM cable)
- Hardware error (power module, controller unit)
- Inform your service agency.
Error message
CC%2 error in cut-out channel STO.A.x (-STO.B.P.x) axis
group A
Cause of error
The cutout channel test detected a fault:
The CC-specific pulse release for the corresponding power
modules of the NC axis group (A) over the A channel is
defective. The ready signal RDY for one axis group is
missing.
The cutout channel STO.A.x was switched to inactive for the
test of the cutout channel STO.B.x for all power modules.
At least one of the acknowledgment signals for this cutout
channel has the wrong condition, i.e. when
- At least one power module reports "No readi-
ness" (RDY.x=0), although "Readiness" (RDY.x=1) is expected
for all power modules of the axis group of the CC.
Error correction
- Check the wiring (e.g. pulse release X72 of the supply
module,
X73 Heidenhain interface PCB, PWM cable is defective)
- Exchange defective hardware (power module)
- Inform your service agency
41
3231

Advertenties

loading