NC-foutmeldingen | Lijst met NC-foutmeldingen
Foutnummer
220-003A
220-003B
220-003C
220-003D
HEIDENHAIN | TNC7 | TNCguide | 01/2022
Beschrijving
Error message
Record al geblokkeerd
Cause of error
An attempt was made to update the tool life in an locked tool
data record.
Error correction
Cancel the lock on the data record (e.g. exit the input with
the "EDIT OFF/ON" soft key),
otherwise it can result in data loss at program end when the
tool life updated.
Error message
Beëindigen van de Cancel-systeemcyclus niet mogelijk %1
Cause of error
Could not complete the cancel system cycle, perhaps becau-
se a PLC strobe was not acknowledged.
Error correction
- Shut down and restart the control (shutdown via error
window,
MORE FUNCTIONS soft key)
- Inform your machine tool builder. He should take the follo-
wing measures:
- Correct the error in the cancel cycle or in the OEM cancel
macro
- Correct the error in the PLC program
Error message
Foute configuratie
Cause of error
Entry appears twice in the list
Error correction
Check the configuration data and edit them if necessary
Error message
Gebruiksduur van gereedschap kon niet worden berekend
Cause of error
- Bij het bepalen van de gebruiksduur van de gereedschap-
pen is een fout opgetreden.
- Bestand GS-gebruik niet aanwezig of niet up-to-date.
Error correction
- Controleer of de gereedschapsgebruiktest via configuratie
is geactiveerd.
- Gebruiksbestand voor NC-programma: programma in de
werkstand Programmatest simuleren, de TNC maakt dan
automatisch het bestand GS-gebruik.
- Gebruiksbestand voor palletbestand: gemarkeerde
programma's in de werkstand Programmatest simuleren, de
TNC maakt dan voor elk gesimuleerd programma automa-
tisch het bestand GS-gebruik.
41