NC-foutmeldingen | Lijst met NC-foutmeldingen
Foutnummer
237-1805B
237-1805C
237-1805D
237-1805E
HEIDENHAIN | TNC7 | TNCguide | 01/2022
Beschrijving
Error message
1805B CC %2 as %1: AVD filter niet stabiel %4
Cause of error
- The parameter set of the AVD filter 13 (type 22) is inconsis-
tent
- The defined frequency of the AVD filter 13 (type 22) is too
high or too low
- The adjusted AVD frequency is too high or too low.
Error correction
- Use the current TNCopt version to check the AVD filter 13.
- Inspect the AVD frequency using TNCopt
- Generation of a new AVD file through TNCopt
- Inform your service agency
Error message
1805C CC %2 as %1: meting met AVD niet stabiel %4
18063 CC %2 as %1: ACC niet stabiel %4
18064 CC %2 as %1: ACC niet stabiel %4
18065 CC %2 as %1: ACC niet stabiel %4
18066 CC %2 as %1: ACC niet stabiel %4
1806B CC %2 as %1: filter niet stabiel %4
Cause of error
- Internal software error
Error message
1805D Maximaal aantal functieblokken overschreden %1
Cause of error
- Maximale aantal LAC-functieblokken overschreden
- Maximale aantal functieblokken van een uitgebreide
compensatie overschreden
Error correction
- Bewerk de uitgebreide compensatiefiles met TNCopt
- Deactivering van de uitgebreide compensaties via
<ParameterSet>.CfgControllerComp.enhancedComp
- Neem contact op met uw servicedienst
Error message
1805E Opschakelpunt in %4, regel %5 niet correct
Cause of error
- Syntaxfout in het weergegeven bestand
- Het opgegeven opschakelpunt wordt niet ondersteund
Error correction
- Aanmaken van een nieuw compensatiebestand met
TNCopt
- Deactivering van de uitgebreide compensaties
- Neem contact op met uw servicedienst