Foutnummer
237-1807E
237-1807F
237-18082
2818
Beschrijving
Error message
1807E CC%s: Internal connection fault, Error code=%4
Cause of error
The component for internal optical fiber connections reports
an error
Possible causes:
- Electromagnetic disturbances
- Hardware defective
Error correction
- Check the encoder cables, particularly shield connections
- Refer to the guidelines in the Technical Manual regarding
the cable routing
- Exchange the hardware
- Create a service file (error code information about the exact
cause of the error for the diagnosis at HEIDENHAIN)
- Contact your service agency
Error message
1807F UM 3xx inverter not found %1
Cause of error
- No communication with the inverter of the displayed axis
- Optical fibers connected incorrectly or not at all
- Supply voltage of the inverter is missing
- The machine parameters CfgAxisHardware->inverterInter-
face, CfgAxisHardware->motorConnector,
or CfgAxisHardware->hsciCcIndex are not parameterized
correctly.
- Inverter defective
Error correction
- Check the cabling
- Check the supply voltage of the inverters
- Check the entries in the machine parameters
- Replace the inverter
- Contact your service agency
Error message
18082 Ingang voor positiemeetsysteem niet aanwezig %1
Cause of error
- Voor het positiemeetsysteem (item in MP_posEncoderIn-
put) is een niet aanwezige ingang geselecteerd
Error correction
- Machineparameter MP_posEncoderInput controleren
- Neem contact op met de servicedienst