NC-foutmeldingen | Lijst met NC-foutmeldingen
Foutnummer
230-032C
230-032D
230-032E
230-032F
230-041A
HEIDENHAIN | TNC7 | TNCguide | 01/2022
Beschrijving
Error message
As %1 (%2): voedingsmodule %3 gedetecteerd en ingevoerd
Cause of error
The named supply module was detected through plug-and-
play and entered in the axis configuration under CfgSupply-
Module->name.
Error correction
Error message
As %1 (%2): plug-and-play voor motor gedeactiveerd
Cause of error
Plug-and-play was deactivated in the named axis for the
motor.
Error correction
- Check the configuration and the motor being used
- Plug-and-play can be reactivated through CfgServoMo-
tor->plugAndPlay
Error message
As %1 (%2): plug-and-play voor omvormer gedeactiveerd
Cause of error
Plug-and-play was deactivated in the named axis for the
inverter.
Error correction
- Check the configuration and the inverter being used
- Plug-and-play can be reactivated through CfgPowerSta-
ge->plugAndPlay
Error message
As %1 (%2): plug-and-play voor voedingsmodule gedeacti-
veerd
Cause of error
Plug-and-play was deactivated in the named axis for the
supply module.
Error correction
- Check the configuration and the supply module being used
- Plug-and-play can be reactivated through CfgSupplyModu-
le->plugAndPlay
Error message
Positie-afwijking (as %2) te groot
Cause of error
De positieafwijking tussen positiemeetsysteem en toerental-
meetsysteem is te groot.
Error correction
Controleer de koppeling tussen positie- en toerentalencoder.