NC-foutmeldingen | Lijst met NC-foutmeldingen
Foutnummer
231-E01A
231-E01A
231-E01A
HEIDENHAIN | TNC7 | TNCguide | 01/2022
Beschrijving
Error message
E01A CC%2 FS-config.fout SS2-reactie ObjId=%5, param=%6
Cause of error
The permissible value range for the safe machine parame-
ters distLimitStop2 or rpmLimitSom3AtSS2 was exceeded.
ObjID = Number of the drive with incorrect configuration
Param = Transferred value
Error correction
- Check the entered value
- Inform your service agency
Error message
E01A CC%2 FS-config.fout SS2-reactie ObjId=%5, param=%6
Cause of error
The permissible value range for the safe machine parame-
ters distLimitStop2 or rpmLimitSom2AtSS2 was exceeded.
ObjID = Number of the drive with incorrect configuration
Param = Transferred value
Error correction
- Check the entered value
- Inform your service agency
Error message
E01A CC%2 FS-config.fout SS2-reactie ObjId=%5, param=%6
Cause of error
Het toegestane waardebereik voor de veilige machinepara-
meter distLimitStop2 of rpmLimitSom4AtSS2 is overschre-
den.
ObjID = nummer van de aandrijving met verkeerde configu-
ratie
Param = doorgegeven waarde
Error correction
- Controleer de ingevoerde waarde
- Neem contact op met de servicedienst
41
2671