For example, if the system is blocked due to water lack, the device automatically starts a test procedure to check whether the machine is really
left definitively and permanently dry. If during the sequence of operations an attempted reset is successful (for example, the water comes back),
the procedure is interrupted and normal operation is resumed.
Table 13 shows the sequences of the operations performed by the device for the different types of blockage..
Display indication
BL
PB
(2)
OT
OC
(2)
7. RESET AND FACTORY SETTINGS
7.1 General system reset
To reset the system, hold down the 4 keys simultaneously for 2 sec. This operation is the same as disconnecting the power, waiting for it to close
down completely and supplying power again. The reset does not delete the settings saved by the user.
7.2 Factory settings
The device leaves the factory with a series of preset parameters which may be changed according to the user's requirements. Each change of
the settings is automatically saved in the memory and, if desired, it is always possible to restore the factory conditions (see Restoring the factory
settings par 7.3 - Restoring the factory settings).
7.3 Restoring the factory settings
To restore the factory values, switch off the device, wait until the display has switched off completely, press and hold down the "SET" and "˄" keys and
turn on the power; release the two keys only when the letters "EE" appear. This restores the factory settings (a message and a rereading on EEPROM of
the factory settings permanently saved in the FLASH memory). Once all the parameters have been set, the device returns to normal operation.
NOTE: Once the factory values have been restored it will be necessary to reset all the parameters that characterise the system (gains, setpoint
pressure, etc.) as at the first installation.
Identifying code
BK
TK
LA
SP
RI
OD
Applicable to firmware versions ≤ 4.x.x
(2)
(3)
Applicable to firmware releases ≥ 4.3.x with integrated connectivity
(4)
Applicable to firmware releases ≥ 4.4.x with integrated connectivity and Multiple Groups functions
Automatic resets of error conditions
Description
Blockage due to water lack
Blockage due to line voltage outside
specifications
Blockage due to overheating of the power
stages
Blockage due to motor overload
Table17: Self-reset of blockages
International factory
Description
Display brightness
Backlight lighting T
Language
Setpoint pressure
Revs per minute in
manual mode
Type of plant
ENGLISH
-
-
-
-
-
-
-
-
Factory settings
Angloamerican factory
settings
80%
/ 50%
(2)
(3) (4)
2 min
English
2,7 bar
3200 rpm
1 (Rigid)
63
Automatic reset sequence
One attempt every 10 minutes for a
total of 6 attempts.
One attempt every hour for a total of 24
attempts
One attempt every 24 hours for a total
of 30 attempts.
It is reset when it returns to a specific
voltage.
It is reset when the temperature of the
power stages returns within the
specifications.
One attempt every 10 minutes for a
total of 6 attempts.
One attempt every hour for a total of 24
attempts.
One attempt every 24 hours for a total
of 30 attempts.
settings
80%
/ 50%
(2)
(3) (4)
2 min
English
39 psi
3200 rpm
1 (Rigid)
Installation Memo