Figure 17.1: Power histogram display
5.1.13 - Output flow meter
The page shows two flow meters. The first shows the total output flow delivered by the machine. The second shows a partial count and can be
reset by the user. The partial count can be reset from this page, by holding down the " ˅ " button for 2 sec.
5.1.14 - NT: Display of network configuration
Information on network and serial connectors. The serial connector can be displayed in full by pressing the "^" key.
5.1.15 - VE: Version Display
Information on the hardware version, serial number and mac address of the pump.
5.1.16 - FF: Fault & Warning display (Log)
Chronological display of the faults that have occurred during system operation. Under the symbol FF appear two numbers x/y indicating
respectively the ault displayed and the total number of faults present; to the right of these numbers is an indication of the type of fault displayed.
The ˄ and ˅ keys scroll through the list of faults: pressing the ˅ key goes back through the log and stops at the oldest fault present, pressing the
˄ key goes forward in the log and stops at the most recent fault. The faults are displayed in chronological order starting from the one that appeared
farthest back in time x=1 to the most recent x=y. The maximum number of faults that can be shown is 64; when that number is reached, the log
starts to overwrite the oldest ones. This item on the menu displays the list of faults, but does not allow reset. Reset can be carried out only with
the dedicated control from item RF on the TECHNICAL ASSISTANCE MENU. The fault log cannot be deleted with a manual reset, by switching
off the appliance, or by resetting the factory values, unless the procedure described above has been followed.
5.2 - Monitor Menu
From the main menu, by holding down simultaneously for 2 sec the keys "SET" and "˅" (minus), or using the selection menu and pressing ˄ or
˅, you can access the MONITOR MENU. In this menu, by pressing the MODE key, the following values are displayed in sequence.
5.2.1 - CT: Display contrast
Parameter not available on pumps with firmware version 3.xx. Adjusts the display contrast.
5.2.2 - BK: Display brightness
Adjusts the backlighting of the display on a scale from 0 to 100.
5.2.3 - TK: Backlight switch-on time
Sets the time that the backlight is lit since the last time a key was pressed. Values allowed: 20 sec to 10 min or always on (even if this option is
selected, the screen will still go into standby mode after a few hours of inactivity to safeguard the integrity of the device). When the backlight is
off, the first time any key is pressed has the sole effect of restoring the backlighting.
5.2.4 - LA: Language
Display in one of the following languages:
• Italian
• English
• French
• German
5.2.5 - TE: Dissipator temperature display
5.3 - Setpoint Menu
From the main menu, hold down simultaneously the "MODE" and "SET" keys until "SP" appears on the display (or use the selection menu pressing
˄ or ˅). The ˄ and ˅ keys allow you respectively to increase and decrease the plant boosting pressure.
Press SET to leave this menu and return to the main menu. The range of adjustment is 1-5.5 bar (14-80 psi).
Applicable to firmware versions ≤ 4.x.x
(2)
(3)
Applicable to firmware releases ≥ 4.3.x with integrated connectivity
(4)
Applicable to firmware releases ≥ 4.4.x with integrated connectivity and Multiple Groups functions
(2)
(3) (4)
• Spanish
• Dutch
• Swedish
• Turkish
ENGLISH
Figure 17.2: Power histogram display
• Slovak
• Romanian
• Russian
• Thai
55
(3) (4)
• Portoguese
(3) (4)
• Polish
(3) (4)
• Chinese
(3) (4)
• Czech
(3) (4)