When the password (PW) is "0" all the parameters are unlocked and can be edited. When a password is used (value of PW different from 0) all
modifications are blocked and "XXXX" is displayed on the page PW.
If the password is set it allows to navigate through all the pages, but at any attempt to edit a parameter a pop-up appears, asking you to type in the
password. When the correct password is typed in the parameters are unlocked and can be edited for 10' after the last key is pressed. If you want to
cancel the password timer, just go to page PW and hold down ˄ and ˅ together for 2". When the correct password is typed in a padlock is shown
opening, while if the wrong password is given a flashing padlock appears. After resetting the factory values the password is set back at "0".
Each change of the password takes effect when Mode or Set is pressed and each subsequent change of a parameter implies typing in the new
password again (e.g. the installer makes all the settings with the default PW value = 0 and lastly sets the PW so as to be sure that the machine is
already protected without any further action).
If the password is lost there are 2 possibilities for editing the parameters of the device:
• Make a note of the values of all the parameters, reset the device with the factory values, see paragraph 7.3. The reset operation cancels all
the parameters of the device, including the password.
• Make a note of the number present on the password page, send a mail with this number to your service centre, in a few days you will be sent
the password to unlock the device.
6. PROTECTION SYSTEMS
The device is equipped with protection systems to preserve the pump, the motor, the supply line and the inverter. If one or more protections trip,
the one with the highest priority is immediately notified on the display. Depending on the type of error the motor may stop, but when normal
conditions are restored the error status may be cancelled immediately or only after a certain time, following an automatic reset.
In the case of blockage due to water lack (BL), blockage due to motor overload (OC), blockage due to direct short circuit between the motor
phases (SC), you can try to exit the error conditions manually by simultaneously pressing and releasing the ˄ and ˅ keys. If the error condition
remains, you must take steps to eliminate the cause of the fault.
In the event of blocking due to one of the internal errors E18, E19, E20, E21 it is necessary to wait 15 minutes with the machine powered until the
blocked status is automatically reset.
Display indication
(2)
Applicable to firmware versions ≤ 4.x.x
(3)
Applicable to firmware releases ≥ 4.3.x with integrated connectivity
Applicable to firmware releases ≥ 4.4.x with integrated connectivity and Multiple Groups functions
(4)
Parameters available in version KIWA
Identifying code
PD
(2)
HL
(2)
Alarm giving advance warning of Blockage due to overheating of the power
OT
OBL
Alarm indicating abnormal temperature recorded on the Low Voltage board
AYS
(3) (4)
AE
(3) (4)
AF
(3) (4)
BAT
(3) (4)
PH
BL
BP1
BP2
PB
(2)
LP
HP
OT
OC
(2)
SC
ESC
HL
NC
E
i
V
i
EY
Table 16: Indications of blockages
ENGLISH
Alarm in the fault log
Description
Irregular switching off
Alarm giving advance warning of Hot Fluid Blockage
amplifiers
"Anti Cycling Smart" function running
"Anti Block" function running
"Anti Freeze" function running
Low battery
Table 15: Fault description
Blockage conditions
Description
Cutout due to pump overheating
Blockage due to water lack
Blockage due to reading error on the delivery pressure sensor
Blockage due to reading error on the suction pressure sensor
Blockage due to supply voltage outside specifications
Block for low DC voltage
Block for high DC voltage
Blockage due to overheating of the power stages
Blockage due to motor overload
Blockage due to short circuit between the motor phases
Blockage due to short circuit to earth
Hot Fluid Blockage
Blockage due to motor disconnected
Blockage due to i-th internal error
Blockage due to i-th internal voltage out of tolerance
Block for cyclicality abnormal detected on the system