5.5.4 - AS: Association of devices
Enables connection/disconnection mode with at the most 2 compatible
elements.
• esy Other Esybox Mini 3 pump for operation in a pump set
composed of max 2 elements
The icons of the various connected devices are displayed on page AS
with below an identifying acronym and the respective reception power.
An icon lit with a fixed light means that the device is connected and
working correctly; a stroked through icon means the device is configured
as part of the network but is not found.
All the devices present on the airwaves are not displayed on this page but only the devices that have been associated with our
network. Seeing only the devices in your own network allows the operation of several similar networks existing within the radius
of action of the wireless without creating ambiguity; in this way the user does not see the elements that do not belong to his
pumping system
From this menu page it is possible to associate and disassociate an element from your personal wireless network. When the machine starts the
AS menu item does not show any connection because no device is associated. In these conditions the message "No Dev" is shown and the
COMM led is off. Only an action by the operator can allow devices to be added or removed with the operations of association and disassociation.
Association of devices
Once on the AS page, pressing "^" for 5 sec puts the machine into wireless association search status, communicating this status with a flashing
of the COMM led at regular intervals. As soon as two machines in a working communication range are put into this status, if possible, they are
associated with each other. If the association is not possible for one or both machines, the procedure ends and a pop-up appears on each machine
saying "association not possible". An association may not be possible because the device you are trying to associate is already present in the
maximum number or because the device to be associated is not recognised. In the last case repeat the procedure from the start.
The search status for association remains active until the device to be associated is detected (irrespective of the result of association); if no device
can be seen within the space of 1 minute, the machine automatically leaves association status. You can leave the search status for wireless
association at any time by pressing SET or MODE. Short-cut. To speed up the procedure, a short-cut has been created that makes it possible to
put the pump in association from the main page by pressing the "˅" key.
IMPORTANT: Once the association has been made between 2 or more devices, a pop-up appears on the display asking you to extend the
configuration. This happens in the case where the devices have different configuration parameters (e.g. setpoint SP, RP etc.). Pressing ^ on a
pump extends the configuration of that pump to the other associated pumps.
When the ^ key is pressed, pop-ups appear with the message "Wait...", and when this message is finished the pumps will start to work regularly
with the sensitive parameters aligned; refer to paragraph 9.3.5 for further information.
Disassociation of devices
To dissociate a device belonging to an existing group, go to page AS (installer menu) of the device itself and press the – key for at least 5 seconds.
After this operation all the icons related to the connected devices will be replaced by the message "No Dev" and the COMM LED will remain off.
Replacing devices
To replace a device in an existing group it is sufficient to dissociate the device to be replaced and to associate the new device as described in the
procedures above. If it is not possible to dissociate the element to be replaced (faulty or not available), you will have to carry out the disassociation
procedure for each device and create a new group.
5.5.5 - EK
: Setting the low pressure function on suction
Present only in models with Kiwa function.
Sets the low pressure function on suction.
5.5.6 - PK
: Low pressure threshold on suction
Present only in models with Kiwa function.
Sets the pressure threshold below which the block is tripped for low pressure on suction.
Applicable to firmware releases ≥ 4.4.x with integrated connectivity and Multiple Groups functions
(4)
Parameters available in version KIWA
(4)
Value
0
1
2
ENGLISH
Function
disabled
enabled with automatic reset
enabled with manual reset
Table 14
58