5. MEANING OF THE INDIVIDUAL PARAMETERS
The inverter makes the system work at constant pressure. This regulation is appreciated if the hydraulic plant downstream from
the system is suitably sized. Plants made with pipes with too small a section introduce load losses that the equipment cannot
compensate; the result is that the pressure is constant on the sensors but not on the utility.
Plants that are excessively deformable can create the onset of oscillations; if this occurs, the problem can be solved by adjusting
the control parameters "GP" and "GI" (see par 5.6.3 - GP: Proportional gain coefficient and 5.6.4 - GI: Integral gain coefficient)
5.1 User Menu
From the main menu, pressing the MODE key (or using the selection menu and pressing ˄ o ˅ ), gives access to the USER MENU. In the menu
the MODE key allows you to scroll through the various menu pages. The values shown are the following.
5.1.1 – Status
Displays the pump status.
5.1.2 - RS: Rotation speed display
Motor rotation speed in rpm.
5.1.3 - VP: Pressure display
Plant pressure measured in [bar] or [psi] depending on the measuring system used.
5.1.4 - VF: Flow display
Displays the instantaneous flow in [litres/min] or [gal/min] depending on the set measuring system. If the recorded measurement is below the
sensitivity threshold of the flow sensor, the measurement value flashes next to the VF identification.
5.1.5 - PO: Absorbed power display
Power absorbed by the electropump in [kW].
If the maximum allowed power is exceeded, the measurement flashes next to the PO identification.
5.1.6 - C1: Phase current display
Motor phase current in [A].
If the maximum allowed current is exceeded, the identification C1 blinks, indicating an imminent tripping of the overload protection.
5.1.7 - SV
: Supply voltage
Present only in some models.
5.1.8 - SR
: Supply range
Present only in some models.
Indicates the range of supply voltage found. It may have the values: [110-127] V or [220-240] V. If the range is not determined, it has the value "- -".
5.1.9 - TE: Dissipator temperature display
5.1.10- PKm
: Pressure measured at intake
Present only in models with Kiwa function
5.1.11 - Operating hours and number of starts
Indicates on three lines the hours that the device has been powered up, the pump working hours and the number of starts of the motor.
5.1.12 - PI: Power histogram
A histogram of the power delivered is displayed on 5 vertical bars. The histogram indicates how long the pump has been on at a given power
level. On the horizontal axis are the bars at the various power levels; on the vertical axis, the time for which the pump has been on at the specific
power level (% of the time with respect to the total).
Parameters available only in the DUAL VOLTAGE version (supply voltage 230 V / 115 V)
Parameters available in version KIWA
ENGLISH