NC-foutmeldingen | Lijst met NC-foutmeldingen
Foutnummer
140-004F
140-0050
140-0051
HEIDENHAIN | TNC7 | TNCguide | 01/2022
Beschrijving
Error message
Config.gegevens updaten
Cause of error
The active machine configuration is not compatible with the
current version of the NC software. The configuration files
belong to an older software version.
Error correction
- After a configuration backup is loaded you have to close
the control down and restart it.
- The code number prompt is shown during start-up. Enter
the code number for the Machine Parameter Editing opera-
ting mode.
- The control implements the configuration data according to
the update rules. Check the changes in the machine configu-
ration and save the edited configuration data.
- Also also read the instructions for updating configuration
data in the Technical Manual.
Error message
Niet-toegestaan gegevensobject voor bestand
Cause of error
Het gegevensobject is op een niet-toegestane plaats
opgeslagen. Het gegevensobject mag helemaal niet in een
parameterbestand worden opgeslagen of het moet zich in
een bestand van de stations-PLC: of SYS: bevinden.
Error correction
Verwijder het gegevensobject volledig uit het bestand of
verplaats het naar een bestand op een ander station. Let er
daarbij ook op welke toegang voor het gegevensobject is
gedefinieerd.
Error message
Gegevensobject '%1' foutief
Cause of error
Een configuratieobject in een configuratiebestand is foutief
of niet volledig.
Mogelijke oorzaken:
- De desbetreffende configuratiegegevens behoren tot een
oudere softwareversie.
- Het gegevensbestand is handmatig bewerkt.
Error correction
- Config-versie herstellen en update opnieuw uitvoeren.
- Met behulp van de Config-Editor het Parameter-object corri-
geren of volledig invullen.
41