Inbedrijfstelling
I
5
Complete parameterlijst
0 0
Par. Naam
Omschakelbare par.
parameterset 1
5__
MONITORING FUNCTIONS
50_
Speed monitoring
500
Speed monitoring 1
501
Decelaration time 1
504
Encoder monitoring
52_
Mains OFF monitoring
520
Mains OFF response time
521
Mains OFF response
53_
Motor temperature protection
530
Sensor type 1
531
Sensor type 2
6__
TERMINAL ASSIGNMENT
60_
Binary inputs basic unit
-
Binary input DIØØ
600
Binary input DIØ1
601
Binary input DIØ2
602
Binary input DIØ3
603
Binary input DIØ4
604
Binary input DIØ5
62_
Binary outputs basic unit
-
Binary output DBØØ
620
Binary output DOØ1
621
Binary output DOØ2
64_
Analog output
640
Analog output AO1
641
Scaling AO1
642
Operating mode AO1
7__
CONTROL FUNCTIONS
70_
Operatings mode
700
Operating mode 1
71_
Standstill current
710
Standstill current 1
70
Instelbereik
After
Fabrieksinstelling
startup
OFF / MOTOR MODE /
REGENERAT. MODE /
MOT.®EN.MODE
0...1...10 s
ON / OFF
0...5 s
CONTROL.INHIBIT
EMERGENCY STOP
No sensor / TF-TH
No sensor / TF-TH
Vaste toewijzing van:
/CONTR.INHIBIT
CW/STOP
CCW/STOP
ENABLE/STOP
n11/n21
n12/n22
Vaste toewijzing van: /BRAKE
READY FOR
OPERATION
NO FUNCTION
ACTUAL SPEED
–10...0...1...10
OFF / 0...20 mA /
4...20 mA
VFC 1
VFC 1 & GROUP
VFC 1 & HOIST
VFC 1 & DC BRAK.
VFC 1 & FLYSTART
VFC-n-CONTROL
VFC-n-CTRL&GROUP
VFC-n-CTRL&HOIST
VFC-n-CTRL&IPOS
CFC
CFC&M-CONTROL
CFC&IPOS
SERVO
SERVO&M-CONTROL
SERVO&IPOS
0...50 % I
Mot
Technische handleiding – MOVIDRIVE
Instelbereik
Par. Naam
Fabrieksinstelling
parameterset 2
OFF / MOTOR MODE /
502 Speed monitoring 2
REGENERAT. MODE /
MOT.®EN.MODE
503 Deceleration time 2
0...1...10 s
De volgende functies kunnen worden geprogrammeerd:
NO FUNCTION • ENABLE/RAP.STOP • CW/STOP •
CCW/STOP • n11(n13) • n21(n23) • n12(n13) • n22(n23) • FIX
SETPT SW.OV. • PAR. SW.OV. • RAMP SWITCHOVER •
MOTOR POT UP • MOT POT DOWN • /EXT. FAULT • FAULT
RESET • /HOLD CONTROL • /LIM. SWITCH CW • /LIM.
SWITCH CCW • IPOS INPUT • REFERENCE CAM •
REF.TRAVEL START • SLAVE FREE RUNN. • SETPOINT
HOLD • MAINS ON • DRS SET ZERO
De volgende meldingen kunnen worden geprogrammeerd:
NO FUNCTION • /FAULT • READY • OUTP.STAGE ON • ROT.
FIELD ON • BRAKE RELEASED • BRAKE APPLIED • MOTOR
STANDSTILL • PARAMETER SET • SPEED REFERENCE •
SPEED WINDOW • SP/ACT.VAL.COMP. • CURR. REFE-
RENCE • Imax-SIGNAL • /MOTOR UTILIZ. 1 • /MOTOR
UTILIZ. 2 • IPOS IN POSITION • IPOS REFERENCE • IPOS
OUTPUT • /IPOS FAULT
De volgende functies kunnen worden geprogrammeerd:
NO FUNCTION • RAMP INPUT • SPEED SETPOINT •
ACTUAL SPEED • ACTUAL FREQUENCY • OUTPUT
CURRENT • ACTIVE CURRENT • UNIT UTILIZATION • IPOS
OUTPUT • RELATIVE TORQUE
VFC 2
VFC 2 & GROUP
701 Operating mode 2
VFC 2 & HOIST
VFC 2 & DC BRAK.
VFC 2 & FLYSTART
711 Standstill current 2
0...50 % I
®
compact MCF/MCV/MCS4_A
After
startup
Mot