Illustration - Feed and return stroke (both programmed as ETR)
Speed
Top Speed
norm rpm
Return rpm
LowSpeed
Feed forward
off
Feed back
off
Pressing the switch on Pin 7 makes the control switch to the inactive state.
Pressing the switch on Pin 4 makes the control switch to the start state.
If the hood switch is released the control shows an error. In this case the control needs to be restarted
and the error has to be acknowledged.
7.2 Automatic without switches – Chipper mode 1:
Active state:
Exceeding norm RPM activates the feeder. Dropping below low speed deactivates the feeder and
activates the retractor for the chosen push time. If the rpm rises above return rpm again the feeder is
activated. Exceeding top rpm deactivates the feeder. The feeder is only reactivated when the rpm
drops below norm rpm again.
If the hood switch is released the control shows an error. In this case the control needs to be restarted
and the error has to be acknowledged.
7.3 Semi-automatic with switches – Chipper mode 2:
Inactive state:
After starting the engine feeder and retractor are deactivated. Pressing the switch on Pin 7 makes the
control switch to the active state. Therefore Pin 4 needs to be connected to ground no matter if it is
configured as normaly open or normally close.
If the hood switch is released the control shows an error. In this case the control needs to be restarted
and the error has to be acknowledged.
Active state:
Exceeding norm RPM activates the feeder. Dropping below low speed deactivates the feeder. The
retractor is not activated.
If the rpm rises above return rpm again the feeder is activated. Exceeding top rpm deactivates the
feeder. The feeder is only reactivated when the rpm drops below norm rpm again.
Pressing the switch on Pin 4 makes the control switch to the inactive state.
If the hood switch is released the control shows an error. In this case the control needs to be restarted
and the error has to be acknowledged.
30/40
Operating Instructions
on
off
off
on
off
Versoin 2.9.4
on
off)* /on
on
off
off
HMCflex
time
time
© ehb Errors expected.