Download Print deze pagina

Jensen A540 DiXL D-1703 E Gebruiksaanwijzing pagina 106

Advertenties

Beschikbare talen

Beschikbare talen

3.1 Schematic overview – [1] Settings
For the factory-set code of the set-up menu, enter 1000 with the arrow keys and confirm the individual
digits with SET. The system now provides the "Set-up Menu" field as shown below. Use the arrow
keys to navigate into the main and submenus and to the individual setting options in "Selection/Input".
Press SET to confirm the offered or selected option. Press "Back" and SET to close the submenu.
[1] Settings
Main menu
[1] language
Language
exit
[2] sensors
Oil pressure
Temperature
pulses/rev
wire W
exit
12/40
Operating Instructions
***Setup Menu***
Pin Nr.: ****
***Setup Menu***
Pin Nr.: 1000
Submenu
SET german, english, francais
SET Return to the selection
SET 0-2bar, 0-3bar, 0-5bar, 0-10bar, 0-16bar, 0-25bar
(In [10] Inputs/Output: "oil" must be set for the sensor,
the menu option is suppressed with "without", "N.O." or
"N.C.".)
SET KTY, PT100, PT1000, 92-027-004, 92-027-006, 92-027-
016, 92-027-022, 92-027-064, 92-027-081, LDW1603
(In [10] Inputs/Output: "temp" must be set for the sensor.)
SET 0.1 - 999.9 Impulses per rotation
SET PNP / (NPN)
Switch to NPN, from hardware version 8.0
The system automatically detects the hardware version.
SET Return to the selection
Attention: the menu selection is adjusted according to the
setting under item
Versoin 2.9.4
Selection/Input
Arrow key
[10] Inputs/Outputs (sensor or switch)!
HMCflex
Note
SET Selection
SET Selection
SET Selection
SET Input
SET Selection
© ehb Errors expected.

Advertenties

loading