Engine running
Engine stopped
SpeedHC CAN
SpeedPC CAN
KL.50F
ALARM_DIV
KL.75
SpeedHC Key
SpeedPC Key
SpeedHC Pin9
SpeedPC Pin9
glow lamp
glow lamp / en-
gine running
Feed forward ETR
20/40
Operating Instructions
active during warning or fault shut-down.
The selected output pin of the D plug has the function of a speed-adjusting
solenoid excitation winding: It is automatically activated after the SpeedMag-
Time has expired when the engine is running.
The selected output pin of the D plug has the function of a speed-adjusting
solenoid pull-in winding: It is automatically activated for approx. 0.5 seconds
after the SpeedMagTime has expired when the engine is running.
The selected output pin of the D plug has the function of a signal output and is
active when the engine is running.
The selected output pin of the D plug has the function of a signal output and is
active when the engine is at standstill.
The selected output pin of the D plug has the function of a speed-adjusting
solenoid excitation winding: A CANBUS message activates or deactivates it
while the engine is running. For example, in combination with an ehb CAN
module ehb5002-14.
The selected output pin of the D plug has the function of a speed-adjusting
solenoid pull-in winding: A CANBUS message activates it for 0.5 seconds
when the engine is running. For example, in combination with an ehb CAN
module ehb5002-14.
The selected output pin of the D plug has the function of a starter output in
direct connection to the starter and features a built-in starter protection. This
prevents unintended starting at running or decelerating engine and protects the
starter, the pinion and the engine gear ring.
The selected output pin of the D plug has the function of a signal output and
returns the status of the "Miscellaneous" input. For the example, the connec-
tion of a tank level switch combined with a horn.
The selected output pin of the D plug has the function of a switched output
KL.75 of the HMCflex ignition starter switch.
The selected output pin of the D plug has the function of a speed-adjusting
solenoid excitation winding: With running engine, activate it with the HMCflex
arrow key
to and deactivate with the arrow key
The selected output pin of the D plug has the function of a speed-adjusting
solenoid pull-in winding: With running engine, activate it with the HMCflex ar-
row key
for approx. 0.5 seconds.
The selected output pin of the D plug has the function of a speed-adjusting
solenoid excitation winding: It is activated at running engine with an earth sig-
nal at Pin 9 of the HMCflex. When the contact is opened, the output is deac-
tivated. For this function, the Ext.Stop (Pin 9) must be set to "Without" in the
Set-up menu [10] Inputs/Outputs.
The selected output pin of the D plug has the function of a speed-adjusting
solenoid pull-in winding: It is activated at running engine with an earth signal at
Pin 9 of the HMCflex for approx. 0.5 seconds. For this function, the Ext.Stop
(Pin 9) must be set to "Without" in the Set-up menu [10] Inputs/Outputs.
The selected output pin of the D plug has the function of a signal output and
only indicates the pre-glow function. The by-glow and after-glow functions are
not indicated.
The selected output pin of the D plug has the function of a signal output and
flashes to indicate the pre-glow function before switching to continuous light
when the engine is running.
This output is active in the chopper function when the speed is within the oper-
ating range (chopper automatic = ON).