After-glowing
Fix time
EGR interval
EGR heat.
Glow function
4.1.5 [5] Generator.Er
time
4.1.6 [6] Autostart
Function
Attempts
Start duration
Start pause
Run-on time
4.1.7 [7] Fault event
oilpress.
temp. max
22/40
Operating Instructions
Specifies the time for after-glowing after the start. The after-glow time is the
result of the determined pre-glow time times the value specified here.
Specifies a fixed glow time in seconds. VG Fct. = fixed time)
Specifies the interval time of the glow plug flashing function in hours. This func-
tion removes deposits from the glow plug or helix.
Specifies the glow time of the flashing function in seconds. (max. 120s)
Select here whether
the pre-glow function is shut-down or the system is to pre-glow
•
temperature-dependent using an external sensor at Pin 3
•
temperature-dependent using an internal NTC sensor
•
with a fixed pre-glow time.
•
As a rule, the generator excitation is switched on while the starter KL.50F is
active. The additional time of generator excitation after successful start can be
set. To be set between 1 and 10 seconds. Setting 0 enables a permanent exci-
tation of the generator while the engine is running.
This function must be set to off!
Number of start attempts. You can program 1 to 5 attempts.
Duration of a start attempt. You can program 1 to 45 seconds.
Time between two start attempts. You can program 1 to 45 seconds.
Additional time to protect the starter preventing a restart after the system has
recognised that the engine is at standstill. The display is off in this state.
The oil level monitoring can be programmed to shut down (emergency off), to
warn (alarm), without monitoring (without) or as shut-down with run-on time
(CDown). "error: oilpress." message
The engine temperature (cylinder head temperature or cooling water tempera-
ture) monitoring can be programmed to shut down (emergency off), to warn
(alarm), without monitoring (without) or as shut-down with run-on time
(CDown). "error: temp. " message
Versoin 2.9.4
HMCflex
© ehb Errors expected.