52 | English
Note
The O-rings installed as standard are primarily suitable for water. If a medium other
than water is pumped, a suitable material must be selected.
2.3.2 Floating ring seal
The pump room is sealed at the motor shaft by a floating ring seal. A small leakage is necessary for
lubrication. Residues may be visible if antifreeze additives or similar are used.
If the pump is not in operation for a longer period of time, it should be put into operation briefly at
regular intervals to avoid increased leakage.
Note
Water additives, especially abrasive materials, can damage the floating ring seal
(increased leakage). Furthermore, no negative pressure must be created at the
floating ring seal.
2.4
Connections
VivarA S
P1
LV
P2
VivarA M from 11 kW
Werkstoff:
VivarA-S 65-340_A71
Anschlüsse P1,P2, LV, M
P1
IL00003700_00
IL00003677_00
Dokumentstatus:
Massstab
1:3
1:3
in Arbeit DS
Format:
A3
Erstelldatum
19.05.2020
PDM_Nr:
205653
Zeichnungsnummer
Biral AG
IL00003677
CH-3110 Münsingen
P2
E
VivarA M
Symbol
LV
Bleeding
LV
sta
Änd. Ind.
Connection on the
00
A
P1
Rev.
Vers.
pressure side
Connection on the
P2
suction side
Intake connection
Pressure connection
LV
E
Drainage, if available
P1
LV
IL00003683_00
P2
Werkstoff:
VivarA-M 65-340_B90
Anschlüsse P1,P2, LV, M
Biral AG
CH-3110 Münsingen
E
Massstab
Dokumentstatus:
1:3
1:3
in Arbeit DS
G
/
"
1
Format:
8
A3
Erstelldatum
20.05.2020
sta
PDM_Nr:
205664
Zeichnungsnummer
Änd. Ind.
IL00003683
00
A
G
/
"
1
Rev.
Vers.
4
G
/
"
1
4
G
/
"
3
8
G
/
"
1
2