13 | Inspiratie en ondersteuning
Foutmelding
Gas burner failed close gas
supply
Service (E) 33.3
Gas burner failed close gas
supply
Service (E) 34.32
Data communication failed
Service (E) 60
Gas system failed
13.3.3
Foutmeldingen verwarming hete lucht
Foutmelding
Service (E) 20.1
Cabinet sensor failed
Service (E) 28.1
Steam generator too hot
Service (E) 28.2
Cooking cabinet too hot
Service (E) 34.1
Data communication failed
Service (E) 34.2
Data communication failed
Service (E) 34.4
Data communication failed
Service (E) 42.3
Solenoid valve failed
Service (E) 42.6
Solenoid valve failed
Service (E) 43.3
Solenoid valve failed
13.3.4
Foutmeldingen vocht
Foutmelding
Service (E) 20.2
Control sensor failed
Service (E) 20.4
Humidity sensor failed
Service (E) 30
Humidity control failed
Service (E) 36
Humidity control failed
62 / 76
Oorzaak
Draai de hoofdkraan van de gasleiding
dicht.
De gasbrander is defect.
Draai de hoofdkraan van de gasleiding
dicht.
De interne datacommunicatie verloopt
gebrekkig.
De initialisering van de ontsteking is
defect.
Schakel het apparaat uit en opnieuw in.
Wanneer de foutmelding blijft bestaan,
moet u contact opnemen met uw
servicepartner.
Oorzaak
De thermometer is defect.
De temperatuurlimiet van de
stoomgenerator is overschreden.
De temperatuurlimiet van de ovenruimte
is overschreden.
De interne datacommunicatie verloopt
gebrekkig.
De interne datacommunicatie verloopt
gebrekkig.
De interne datacommunicatie verloopt
gebrekkig.
De watertoevoer is defect.
De watertoevoer is defect.
De interne watertoevoer gaat niet meer
dicht.
Oorzaak
De thermometer is defect.
De thermometer is defect.
De vochtigheidsmeting is defect.
De drukverschilsensor is defect.
Bereiding mogelijk
Nee
Ja
–
Bereiding mogelijk
Nee
Nee
Nee
Nee
Nee
Nee
U kunt niet meer beschikken
over de functie Stoomstoot.
Ja
U kunt alleen nog beschikken
over de bedrijfsmodus
Hetelucht.
Bereiding mogelijk
Ja
Ja
Ja
Ja