PROBLEM
The gate does not
open or close.
.
Acquisition
procedure does
not complete
correctly.
Remote control
has limited range
and does not work
while automated
gate is moving.
is not working.
With gate stops,
(ASSt)
regular duty cycle
(1 s on / 4 s off).
Message
(POS1)
together with
audible warning
signal.
(with SMARTY/
EMA only)
(POS2)
Gate open
indicator lamp
does not work.
Gate does not
perform desired
manoeuvre.
N.B.: Press the TEST button to temporarily cancel the alarm.
The next time a command is received, the alarm reappears on the display if the problem has not been resolved.
ALARM
POSSIBLE CAUSE
Incorrect installation of the motors
Position detected of MOTOR 2
incongruent with travel length.
Incorrect installation of the motors
(btLO)
Flat batteries.
The motor supply voltage is dropping,
the control unit is assessing whether
this is due to a broken fuse or actual
low battery voltage.
TEST button pressed accidentally.
Safety devices in alarm state.
Excessive voltage drop.
Travel length error.
The radio transmission is impeded
by metal structures and reinforced
concrete walls.
Flat batteries.
wires disconnected.
Maintenance alarm.
reading is in progress.
reading is in progress.
Bulb blown or wires disconnected.
Motor leads crossed.
Incorrect selection of the battery type. Change the value of the parameter
ACTION
Verify the correct installation of the motors.
SMARTY motors with SMARTY/EMA installed
must not be installed to open the door
Check the setting of parameter
the learning procedure.
Replacing the encoder is recommended if the
problem persists.
Verify the correct installation of the motors.
SMARTY motors with SMARTY/EMA installed
must not be installed to open the door
Wait for mains power to be restored.
No intervention, it is a waiting phase to give a
Repeat acquisition procedure.
Press the TEST button and check the safety
device/s in alarm state and the connections
of the safety devices.
Repeat acquisition procedure.
Check mains voltage.
Move gate into completely closed position
and repeat the procedure.
Install the antenna.
Replace the transmitter batteries.
Check LED circuit and/or connector wires.
Perform a maintenance programm.
To reset the alarm, release the protection
by inputting the password (
TEST for 5 s. The message
followed by the messages
4 seconds: to reset the alarm, hold down the
TEST key until
is displayed.
If the TEST key is released,
the display and the alarm is not reset.
The manoeuvre counter resets.
The number of hours
is stored by the
control unit, and the count is reset.
N.B.: when 8000 hours of manoeuvres are
exceeded, the maintenance alarm is disabled
entirely.
At start of each manoeuvre, the control unit
acquires the position of MOTOR 1.
If the position is not read successfully, the
message
is shown on the display.
At start of each manoeuvre, the control unit
acquires the position of MOTOR 2.
If the position is not read successfully, the
message
is shown on the display.
Check the bulb and/or wires.
and repeat
) and press
is displayed,
appears on
.
73