1
Symbols
The symbols and their meaning in the manual or on the product label are indicated below.
Generic danger
Important safety information. Indicates operations and situations in which the personnel involved
must pay close attention.
Dangerous voltage risk
Indicates operations and situations in which the personnel involved must pay close attention to
dangerous voltages.
Useful information
Indicates useful information for the installation.
Refer to the Installation and use instructions
Indicates the obligation to refer to the manual or original document, which must be available for
future use and must not be damaged in any way.
Protective earth connection point.
Indicates the admissible temperature range.
Alternating current (AC)
Direct current (DC)
Symbol for the product disposal according to the WEEE directive.
2
Product description
The 36V
EDGE1 control unit controls 1 or 2 ROGER brushless motors in sensorless mode for applications on large
sized or heavy gate wings.
Ensure that the parameter
may not function properly.
Use the same type of motor for both gate leaves in automation installations for double leaf swing gates.
ensuring that the gate leaves overlap correctly.
ROGER TECHNOLOGY cannot be held responsible for any damage or injury due to improper use or any use other than
the intended usage indicated in this manual.
recommend installing F4ES or F4S series photocells.
For further information, refer to the automation installation manual of the connected automation
3
Updates of version P4.30
1. Improved inverter management for High Speed motors.
2. Added the management of the IP device B74/BCONNECT controllable via browser device Roger BCONNECT, for the complete
management via IP, through the connection on WiFi network, of the EDGE1 control panels. The connection is possible in proximity
of the installation of the automation with access point functionality directly provided by B74/ BCONNECT (point to point connection)
or through the registration and the activation to the cloud Roger Technology with the possibility to manage all the functions of the
central unit remotely via web browser.
3. Possibility of FW update of the central unit in point-to-point mode (at the place of installation), or via browser (remotely via cloud or
from another device connected to the same network).
4. Addition of "remote assistance" mode and automation management with "emergency functionality" enabled and managed by web browser.
5. Added par.
to time reclosing after partial opening.
6. Also enabled the PED command to perform position recovery.
7. Improved management of the sensitive 4.1 kOhm ribs (setting par.
is set correctly. If this parameter is not set correctly, the automation system
and
to value 12).
47