4
Technical characteristics of product
MAINS POWER VOLTAGE
MAXIMUM MAINS POWER ABSORPTION
INRUSH POWER
FUSES
CONNECTABLE MOTORS
MOTOR POWER SUPPLY
MOTOR TYPE
MOTOR CONTROL TYPE
RATED MOTOR POWER
MAXIMUM MOTOR POWER
MAXIMUM POWER, FLASHING LIGHT
FLASHING LIGHT DUTY CYCLE
MAXIMUM POWER
GATE OPEN LIGHT POWER
ELECTRIC LOCK POWER
MAXIMUM ACCESSORY CURRENT ABSORPTION
OPERATING TEMPERATURE
DEGREE OF PROTECTION
PRODUCT DIMENSION
(*) The electric lock output provides a voltage of 36V
The device to be connected must therefore be able to withstand a maximum voltage of 40V .
The total of the absorption values of all the accessories connected must not exceed the maximum power values
shown in the table. The values are guaranteed with original ROGER TECHNOLOGY accessories ONLY. The use of
non-original accessories may lead to malfunctioning. ROGER TECHNOLOGY declines all responsibility for incorrect or
non-conforming installations.
All the connections are protected by fuses (refer to the table). The courtesy light requires an external fuse.
48
EDGE1/BOX
230V~ ± 10% 50 Hz
230 W
600 W
F1 = 20A (ATO257) motor power circuit protection
F2 = 4A (ATO257) electric lock protection
F3 = 3A (ATO257) accessories power supply protection
F4 = T2A (5x20 mm) primary transformer coil protection
2
36V~, with self-protected inverter
Sinusoidal drive brushless (ROGER BRUSHLESS)
60 W
250 W
25 W (24V
)
50%
100 W 230V~ - 40 W 24V~ /
3 W 24V
15 W 12V
(medium voltage) (*)
20 W 24V
(750 mA)
-20°C
+55°C
IP54
dimensions in mm 330x230x115 Weight: 3,9 kg
nominal (max 40V ) modulated to 30% (30% ON, 70% OFF).
EDGE1/115/BOX
115V~ ± 10% 60 Hz
(potential free contact)