Selecting the type of photocell test on input FT1
This parameter is visible if
If the photocell test is enabled, the control unit will check the photocells connected to input FT1 are working properly.
The test lasts max. 3 s OFF / 3 s ON.
Selecting the type of photocell test on input FT2
This parameter is visible if
If the photocell test is enabled, the control unit will check the photocells connected to input FT2 are working properly.
The test lasts max. 3 s OFF / 3 s ON.
Photocell test disabled.
Photocell test enabled on opening ONLY.
Photocell test enabled on closure ONLY.
Photocell test enabled on both opening and closure.
Reversibility management for SMARTY 5R5-SMARTY 7R automations
This parameter is visible ONLY if
The mechanism of the SMARTY 5R5/7R is REVERSIBLE. This parameter if enabled helps to limit the effects of reversibility.
NOTE: Even though it is a REVERSIBLE unit, the motor is equipped with a lock release system.
The motor of the SMARTY 5R5/7R does not resist any external forces.
It is therefore possible to move the leaf manually, in any direction, without unlocking the motor.
The motor of the SMARTY 5R5/7R is used as a holding brake when the power is on and when it is not rotating, holding
the leaf in position with a certain braking torque. An external force applied to the leaf, if greater than the force exerted
by the motor, will cause the leaf to move manually.
ATTENTION: If the automation is to be locked in the fully open or fully closed position, it is MANDATORY to install an
electric lock.
Setting motor stop distance
01= faster deceleration/shorter stop distance ... 05= slower deceleration/longer stop distance.
Select number of motors installed
N.B.:
(see chapter 10).
1 motor.
2 motors. IMPORTANT: Use the same type of motor for both gate leaves.
Enabling absolute encoder (SMARTY Series automation systems only)
Attention: the parameter
REVERSIBLE motor.
NB: the position data request message
PROG key until
Attention: SMARTY motors with SMARTY/EMA installed must not be installed to open the door towards the outside
Disabled.
Enabled. Perform or repeat the acquisition procedure to acquire the parameters relative to the installation. N.B: see
chapter 12 for more information on the absolute encoder.
Sensing edge NOT INSTALLED.
NC contact (normally closed). The gate reverses only when opening.
Contact with 8k2 resistor. The gate reverses only when opening.
NC contact (normally closed). The gate always reverses.
Contact with 8k2 resistor. The gate always reverses.
Management of two 8k2 sensitive edges connected in parallel (total resistance 4k1). The gate reverses only when
opening.
Management of two 8k2 sensitive edges connected in parallel (total resistance 4k1). The gate always reverses.
Sensing edge NOT INSTALLED.
66
N.C.
8k2
or
is set.
or
is set.
or
must be set and SMARTY/EMA installed for all applications with the SMARTY
appears on the display, then repeat the acquisition procedure (see chapter 10).
COS1
COS2
8k2
8k2
.
8k2
8k2