5.1. My Booster...
A.
Does not recharge anymore:
There is no current on the wall socket (230V or 110V AC) on which you have
connected the charger.
The charger does not function any more.
The recharge plug of the Booster is damaged (see point 4.1. (point 5)).
The batteries are sulphated, swollen or « cooked » and do not take anymore the
charge.
B.
Does not work anymore in 12V, either in 24V:
The fuse inside melted (see point 3.5.).
C.
Has no power anymore:
The Booster is not charged (see point 5.1. - A).
The batteries lost its power because of:
The sulphatation of the batteries: you did not recharge your Booster regularly.
A recharge with a non automatic garage charger or an automatic charger in
position « fast charge » or « boost ». *
A connection of the Booster in position 12V to a vehicle 24V during a short
time. *
An element inside a battery melted because of:
Starting attempts superseding the user instructions (see point 3.4.).
A battery is « cooked » because of:
A connection of the Booster in position 12V to a vehicle 24V. *
A recharge on a non automatic garage charger (more than 14,4V tension). *
The batteries are swollen because of:
A recharge with a non automatic garage charger or in position « fast charge » or
« boost », or a recharge of the Booster when the battery is deeply discharged. *
* Attention: Explosion risk !!!