4. Preventing premature failure of your Booster's
batteries
Correctly recharging the Booster batteries, increases
4.1. Recharging
1.
The Booster must be imperatively put on permanent charge between use.
 Why ?
Below 12,4V, the Booster batteries will start to sulphate and irreversible lose
performance. The lower the voltage, and the longer the time spent in a discharged
state, the deeper the sulphation. When not in use, the Booster batteries must
never drop below 12,4V (well-charged = 13V).
 Illustrated explanation:
Composition of a lead-acid battery:
sulfuric acid
electrolyte
66
its efficiency and its lifetime !
3/4
1/4
distilled water
electric
lead
charge
battery