Preparations to made by the customer

1.0.6
The preliminary steps to be taken by the customer are:
- Installation of the equipment in the place of use (the cold room must have a suitable hole to house the evaporating unit).
- Installation of a suitable electrical protection device upstream the unit
- Implementation of the electrical links (supply and control), following the electrical diagram attached.
- Implementation of plumbing links (including possible pipes for condensate drain).

Instructions for service intervention requests and spare parts orders

1.0.7
When requesting any information or technical intervention for the machine, it is obligatory to state the name and serial number of the
model as well as the nature of the fault. The plate is fixed to the side of the machine and it's shown in the declaration of conformity.
Often operating malfunctions are due to trivial causes and therefore, before requesting the intervention of a technician, please consult
the "Troubleshooting" section. When identifying replacement parts, always refer to the machine model.
Caution! We recommend the use of original replacement parts. The Manufacturer declines all liability for the use of replacement parts
that are not original. The replacement of worn parts is allowed only to qualified personnel or to producers.

Glossary of terms

1.0.8
- Compressor. An organ of the refrigerating system that is able to intake the refrigerant in its gas state and compress it as it is released
at a higher pressure.
-
Condenser and Evaporator. Heat exchangers where the "exchange of heat" occurs between the refrigerant and the surrounding air.
-
Grid. A protective element for mechanical moving parts, which also consents the passage of air.
-
Fan. A mechanical organ which moves air through the heat exchangers.
-
Refrigerating Circuit. A body composed of parts that contain refrigerant and which are joined together to form a closed refrigerating
circuit in which the refrigerant circulates to absorb or release heat.
-
Defrosting. A process in which the ice formed between the evaporator fins is melted by raising the temperature by hot gas of the
compressor.
-
Control Panel. An electronic device for the control of all machine functions.
-
Cold Room. A room insulated against heat for the storage and conservation of perishable goods at a temperature that is different to
that of the ambient temperature level.

1.1 Machine transport and handling

The machines are protected during transport by particularly sturdy packing which is resistant to various stresses.
In spite of its low dimensions the packaged machine cannot be transported manually.
The correct lifting system to use is a fork lift or pallet conveyor/mover, making sure that the weight of the machine is evenly distributed.
For highest safety during transport and handling, the equipment contained inside the packing has been screwed down to the pallet.
The packing has printed warning symbols that represent the instructions to follow during transport and storage in order to assure that no
damage is caused to the equipment during loading and unloading operations
The symbols printed on our packing are as follows (UNI ISO 780):
HANDLE WITH CARE
16
THIS WAY UP
PROTECT FROM MOISTURE
Manual
FORK HERE