Pump model
Pump type
DMH 272-16
DMH 340-16
DMH 440-10
DMH 450-16
DMH 520-16
DMH 575-10
DMH 257
DMH 680-16
DMH 750-4
DMH 770-10
DMH 880-10
DMH 1150-10
DMH 1500-4
* Dosing capacity per dosing head; double the capacity for double-head pumps.
** Maximum counterpressure
The pump can be operated in the range between 10
Note
% and 100 % of the maximum dosing capacity.
3.3.2 Accuracy
•
Dosing flow fluctuation: smaller than ± 1.5 % within the control
range 10-100 %
•
Linearity deviation: ± 2 % of the full-scale value.
Applies to:
•
water as dosing medium
•
fully deaerated dosing head
•
standard pump version.
3.3.3 Maximum inlet pressure
Pump model
DMH 251
DMH 252
DMH 253
DMH 254
DMH 255
DMH 257
10
50 Hz
Max.
Q*
p max.**
stroke
rate
[l/h]
[bar]
[n/min]
272
16
56
340
16
73
440
10
56
450
16
98
520
16
112
575
10
73
680
16
146
750
4
73
770
10
98
880
10
112
1150
10
146
1500
4
146
3.3.4 Minimum counterpressure at the discharge valve of the
Pump model
All
Note
[bar]
8
8
5
5
0.8
0.8
60 Hz
Max.
Q*
p max.**
stroke
rate
[l/h]
[bar]
[n/min]
326
16
67
408
16
88
528
10
67
540
16
118
624
16
134
690
10
88
-
-
-
900
4
88
924
10
118
1056
10
134
-
-
-
-
-
-
pump
A positive pressure difference of at least 2 bar is
required between the suction valve and the
discharge valve in order for the dosing pump to
operate correctly.
If the total counter-pressure (at the dosing point) and
geodetic height difference between the suction valve
and the dosing point is less than 2 bar (20 m WC), a
pressure-loading valve must be installed immediately
before the dosing point.
100 Hz
Max.
Q*
p max.**
stroke
rate
[l/h]
[bar]
[n/min]
544
16
112
680
16
146
880
10
112
-
-
-
-
-
-
1150
10
146
-
-
-
1500
4
146
-
-
-
-
-
-
-
-
-
-
-
-
[bar]
2