Parameterbeschrijving
13-15 RS-FF Operand S
Option:
[95]
RS Flipflop 1
[96]
RS Flipflop 2
[97]
RS Flipflop 3
[98]
RS Flipflop 4
[99]
RS Flipflop 5
[100]
RS Flipflop 6
[101]
RS Flipflop 7
13-16 RS-FF Operand R
Option:
[0]
FALSE
[1]
TRUE
[2]
Actief
[3]
Binnen bereik
[4]
Op referentie
[5]
Koppelbegrenzing
[6]
Stroombegr.
[7]
Buiten stroombereik
[8]
Onder I, laag
[9]
Boven I, hoog
[10]
Buiten snelh.-bereik
[11]
Onder snelh., laag
[12]
Boven snelh., hoog
[13]
Buiten terugk.bereik
[14]
Onder terugk., laag
[15]
Boven terugk., hoog
[16]
Therm. waarsch.
[17]
Netsp. buiten bereik
[18]
Omkeren
[19]
Waarschuwing
[20]
Alarm (uitsch.)
[21]
Alrm (uitsch & blok)
[22]
Comparator 0
[23]
Comparator 1
[24]
Comparator 2
[25]
Comparator 3
[26]
Log. regel 0
[27]
Log. regel 1
[28]
Log. regel 2
[29]
Log. regel 3
[30]
SL time-out 0
[31]
SL time-out 1
[32]
SL time-out 2
[33]
Digitale ingang DI18
[34]
Digitale ingang DI19
[35]
Digitale ingang DI27
[36]
Digitale ingang DI29
[37]
Digitale ingang DI32
[38]
Digitale ingang DI33
[39]
Startcommando
[40]
Omv. gestopt
[41]
Reset uitsch.
[42]
Autoreset uitsch.
®
VLT
AutomationDrive Programmeerhandleiding
Functie:
Functie:
®
MG33MF10 – VLT
is een gedeponeerd handelsmerk van Danfoss
13-16 RS-FF Operand R
Option:
[43]
Toets OK
[44]
Toets Reset
[45]
Toets links
[46]
Toets rechts
[47]
Toets omhoog
[48]
Toets omlaag
[50]
Comparator 4
[51]
Comparator 5
[60]
Log. regel 4
[61]
Log. regel 5
[70]
SL time-out 3
[71]
SL time-out 4
[72]
SL time-out 5
[73]
SL time-out 6
[74]
SL time-out 7
[75]
Startcomm. gegeven
[76]
Dig. ingang X30/2
[77]
Dig. ingang X30/3
[78]
Dig. ingang X30/4
[79]
Digital input x46/1
[80]
Digital input x46/3
[81]
Digital input x46/5
[82]
Digital input x46/7
[83]
Digital input x46/9
[84]
Digital input x46/11
[85]
Digital input x46/13
[90]
ATEX ETR cur. warning
[91]
ATEX ETR cur. alarm
[92]
ATEX ETR freq. warning
[93]
ATEX ETR freq. alarm
[94]
RS Flipflop 0
[95]
RS Flipflop 1
[96]
RS Flipflop 2
[97]
RS Flipflop 3
[98]
RS Flipflop 4
[99]
RS Flipflop 5
[100]
RS Flipflop 6
[101]
RS Flipflop 7
3.14.5 13-2* Timers
Gebruik het resultaat (TRUE of FALSE) van timers om
rechtstreeks een gebeurtenis te definiëren (zie 13-51 SL
Controller Event) of als booleaanse ingang in een logische
regel (zie 13-40 Logische regel Boolean 1, 13-42 Logische
regel Boolean 2 of 13-44 Logische regel Boolean 3). Een timer
is alleen FALSE als deze wordt geactiveerd door een actie
(d.w.z. Start timer 1 [29]) totdat de ingestelde tijd in deze
parameter is verstreken. Daarna wordt hij weer TRUE.
Alle parameters in deze parametergroep zijn arraypara-
meters met index 0 tot 2. Selecteer index 0 om timer 0 te
programmeren, index 1 om timer 1 te programmeren,
enzovoort.
Functie:
3
3
127