6. Remove two mounting bolts holding valve bracket to
hoodstand. See Fi g. 7-2.
7. Remove the valve and hose assembly, guiding the hoses
through the large grommet in the frame.
For proper hose connections, see Fig. 7-5.
After re-
assembling, check transaxle oil level after running the engine
and operating the lift system for one (1) minute.
I
ION
~
Fig. 7-5 C-Series Hydraulic Valve Hose Connections
Remove Hydraulic Valve Handle
1.
Remove left side panel.
2. Disconnect battery negative terminal.
Fig. 7-6 C-Series Hydraulic Valve
3. Remove ammeter mounting panel and disconnect two
(2) connections from ammeter.
4. Remove controls cover plate.
5. Remove two mounting bolts holding valve bracket to
frame. See Fig. 7-2.
6. Tilt valve for access to push nut and pin.
7. Replace handle and reassemble using new push nut.
7-3
SECTION 7
Overhaul Hydraulic Valve
1. Remove valve and hoses from tractor (see Remove
Hydraulic Valve).
Q
Fig. 7-7 C-Series Hydraulic Valve Overhaul
2. Remove spool cap and 1/8 inch allen bolt.
3. Replace "0" ring and spring.
When reassembling valve, make sure Allen h e a d : : !
clears washer under spring.
-.-J
Remove Hydraulic Hoses
The entire hydraulic valve must be removed to replace
any or all hoses. Follow procedure for Remove Hydraulic
Valve.
D-SERIES, Automatic
Attachments Mounting Locations
The lift bellcrank No. 1 in Fig. 7-8 is actuated by the
hydraulic lift cylinder.
For each attachment, a specific hole in the lift
bell-
crank is used for mounting attachments. The following
chart depicts the lift bellcrank hole to be used for a specific
attachment.