Index
13
PO 3 Setpoint P096 ............................................88
PO data enable P876 .......................................111
Premagnetization time ........................................98
Premagnetization time 1 P323 ............................98
Premagnetization time 2 P333 ............................98
Prioriteit bedrijfstoestanden ..............................142
Procesingangsdatawoorden .............................111
Process values ....................................................86
Procesuitgangsdatawoord ................................110
PROFIBUS DFP21B .................................... 76
PROFINET DFE32B ..............................79
Programmeerapparaat
status binaire ingangen / uitgangen ...........221
Programmeerapparaat DBG60B .........................44
inbedrijfstelling ............................................195
parameters instellen ...................................201
Programmeerapparaat FBG11B ................ 41
bediening ....................................................189
functies .......................................................188
inbedrijfstelling ............................................193
Programmeerapparaat, statusindicaties ...........221
Protocolvarianten ...................... 76
PTC-remweerstand .............................................51
PTC-remweerstanden .......................................121
PWM fix 1 P862 ................................................110
PWM fix 2 P863 ................................................110
PWM frequency ................................................110
PWM frequency 1 P860 ....................................110
PWM frequency 2 P861 ....................................110
PWM-frequentie ................................................118
R
Ramp t11 down P131 .........................................95
Ramp t11 up P130 ..............................................95
Ramp t21 down P141 .........................................95
Ramp t21 up P140 ..............................................95
Ramp t3 motor potentiometer P150 ....................96
Rated output current P071 ..................................87
Reactietijden klemmen ........................................21
reference signals .................................................99
Referentiemelding PI-regelaar ..........................100
Regelaar-/motorcombinaties .............................117
Relaisuitgang ......................................................20
Remaansturing ..................................................125
Remgelijkrichter ................................................125
Remgelijkrichter, aansluiting .............................178
Remparameters ................................................125
Remweerstand BW .............................................51
Remweerstand BW, aansluiting ........................177
248
Remweerstand in vlakke bouwvorm .................. 52
Remweerstand in vlakke bouwvorm,
montage onder regelaar ..................................... 59
Remweerstand, aansluiting .............................. 160
Remweerstand, configuratie ............................ 120
Remweerstand, draadweerstand ....................... 53
Remweerstand, lamellenweerstand ................... 53
Remweerstand, PTC .......................................... 51
Remweerstand, vlakke bouwvorm ..................... 52
,
Remweerstanden
81
,
,
80
82
Remweerstanden BW, maatschetsen ................ 56
Reparatieservice .............................................. 233
,
188
Reset ................................................................ 229
Reset behavior ................................................. 109
,
,
,
,
79
80
81
82
Reset statistical data P804 .............................. 108
Response /EXT. FAULT P830 ......................... 109
Response to brake wear P549 ......................... 101
Response to drive vibration / fault P541 .......... 101
Response to drive vibration / warning P540 ..... 101
Response to oil aging / fault P543 ................... 101
Response to oil aging / warning P542 ............. 101
Response to RS-485 timeout P833 ................. 109
Response to SBus timeout P836 ..................... 109
Returncode
Returncodes ..................................................... 220
Rijwerken ......................................................... 114
RS-485 address ............................................... 109
RS-485 address P810 ...................................... 109
RS-485 group address P811 ........................... 109
RS-485 remote timeout P812 .......................... 109
RS-485, installatie ............................................ 183
RUN (programmeerapparaat FBG11B) ........... 188
draadweerstand ......................................... 122
lamellenweerstand ..................................... 122
PTC ........................................................... 121
vlakke bouwvorm ....................................... 122
basisapparaat ............................................ 229
interface ..................................................... 229
programmeerapparaat ............................... 229
19 Parameterblokkering geactiveerd ......... 220
20 Fabrieksinstelling actief ........................ 220
23 Optiekaart ontbreekt ............................. 220
27 Optiekaart ontbreekt ............................. 220
28 Regelaarblokkering noodzakelijk .......... 220
29 Ongeldige waarde voor parameter ....... 220
32 Vrijgave ................................................. 220
34 Fout in procedure ................................. 220
38 FBG11B verkeerde dataset .................. 220
Systeemhandboek V2 – MOVITRAC
®
B