13. REFRIGERANT DIAGRAM
T2B
21
HP
LP
EN
130
Indoor unit
INDOOR UNIT
6
7
9
10
13
17
TW_out
21
6
TW_i n
23
SP
IBH
24
36
T1
23
AS Sacrificial anode
T2
FL
24
Cod. 354M000010 - Rev. 03 - 06/2023
Water drain
Water loading
DHW outlet
DHW inlet
DHW storage tank
ction
Check valve
DHW expansion vessel (not supplied)
Expansion vessel
Water pressure gauge
Automatic air vent valve
Flow switch
Outdoor unit
Cooling
Heating
OMNIA SW-T 3.2
G
Gas Line
L
Liquid Line
Pi
Water circulating pump
mostat
SP Plate heat exchanger
SV1 Diverter valve
-
T1
Heat pump outlet water temperature probe
T2
Heat pump liquid coolant temperature probe
T2B Heat pump refrigerant gas temperature probe
T5
DHW storage tank probe
TBH DHW storage tank heating element
TW_in
Plate heat exchanger inlet water tempe-
rature probe
TW_out
Plate heat exchanger outlet water tem-
perature probe
Legenda unità esterna
E1
Compressore
E2
Valvola a 4 vie
E3
Separatore gas-liquido
E4
Scambiatore di calore lato aria
E5
Valvola di espansione elettronica
E6
Valvola elettromagnetica unidirezionale
E7
Filtro
E8
Sensore di temperatura di scarico
E9
Sensore di temperatura esterna
E10 Sonda scambiatore esterno
E11 Valvola di arresto (gas)
E12 Valvola di arresto (liquido)
E13 Pressostato di alta pressione
E14 Interruttore di bassa pressione
E15 Sensore di pressione
E16 Capillare
E17 Sensore di temperatura di aspirazione
-