Parameterbeschrijving
8-14 Instelbaar stuurwoord CTW
Option:
3
3
8-17 Configurable Alarm and Warningword
Het instelbare alarm- en waarschuwingswoord bestaat uit 16 bits
(0-15). Elk van deze bits kan worden ingesteld op een van de
volgende opties.
Option:
[0]
*
[1]
[2]
[3]
[4]
[5]
[6]
[7]
[8]
[9]
[10]
[11]
[12]
[13]
[14]
[17]
[19]
[22]
[23]
[24]
[25]
[26]
[27]
[28]
[29]
[30]
[31]
[32]
[34]
[36]
[40]
[41]
[45]
[47]
[58]
[59]
[60]
[61]
[62]
[64]
[65]
[66]
[68]
[73]
132
Functie:
[6] Wikkelmachine, [7] Uitgebr PID snh gn tk of [8]
Uitgebr PID snelh + tk.
Off
10 Volts low warning
Live zero warning
No motor warning
Mains phase loss warning
DC link voltage high warning
DC link voltage low warning
DC overvoltage warning
DC undervoltage warning
Inverter overloaded warning
Motor ETR overtemp warning
Motor thermistor overtemp warning
Torque limit warning
Over current warning
Earth fault warning
Controlword timeout warning
Discharge temp high warning
Hoist mech brake warning
Internal fans warning
External fans warning
Brake resistor short circuit warning
Brake powerlimit warning
Brake chopper short circuit warning
Brake check warning
Heatsink temperature warning
Motor phase U warning
Motor phase V warning
Motor phase W warning
Fieldbus communication warning
Mains failure warning
T27 overload warning
T29 overload warning
Earth fault 2 warning
24V supply low warning
AMA internal fault warning
Current limit warning
External interlock warning
Feedback error warning
Frequency max warning
Voltage limit warning
Controlboard overtemp warning
Heatsink temp low warning
Safe stop warning
Safe stop autorestart warning
Danfoss A/S © 05/2015 Alle rechten voorbehouden.
®
VLT
AutomationDrive FC 301/302
8-17 Configurable Alarm and Warningword
Het instelbare alarm- en waarschuwingswoord bestaat uit 16 bits
(0-15). Elk van deze bits kan worden ingesteld op een van de
volgende opties.
Option:
[76]
[77]
[78]
[89]
Functie:
[163]
[165]
[10002]
[10004]
[10007]
[10008]
[10009]
[10010]
[10011]
[10012]
[10013]
[10014]
[10016]
[10017]
[10022]
[10026]
[10027]
[10028]
[10029]
[10030]
[10031]
[10032]
[10033]
[10034]
[10036]
[10037]
[10038]
[10039]
[10045]
[10046]
[10047]
[10048]
[10049]
[10060]
[10061]
[10063]
[10065]
[10067]
[10068]
[10069]
[10073]
[10074]
[10075]
[10078]
[10079]
Power unit setup warning
Reduced powermode warning
Tracking error warning
Mech brake sliding warning
ATEX ETR cur limit warning
ATEX ETR freq limit warning
Live zero error alarm
Mains phase loss alarm
DC overvoltage alarm
DC undervoltage alarm
Inverter overload alarm
ETR overtemperature alarm
Thermistor overtemp alarm
Torque limit alarm
Overcurrent alarm
Earth fault alarm
Short circuit alarm
CTW timeout alarm
Hoist brake alarm
Brake powerlimit alarm
Brakechopper shortcircuit alarm
Brake check alarm
Heatsink temp alarm
Phase U missing alarm
Phase V missing alarm
Phase W missing alarm
Inrush fault alarm
Fieldbus com faul alarm
Mains failure alarm
Phase imbalance alarm
Internal fault
Heatsink sensor alarm
Earth fault 2 alarm
Powercard supply alarm
24V supply low alarm
1.8V supply low alarm
Speed limit alarm
Ext interlock alarm
Feedback error alarm
Mech brake low alarm
Controlboard overtemp alarm
Option config changed alarm
Safe stop alarm
Powercard temp alarm
Safestop auto restart alarm
PTC thermistor alarm
Illegal profile alarm
Tracking error alarm
Illegal PS config alarm
Functie:
MG33MK10