If the case occurs the following may appear:
Fault indications
Warning indications
Specific icons
The error conditions are indicated in Table 8. The other displays are indicated in Table 4.
Error and status conditions displayed
Identifying code
GO
SB
DIS
F4
Low suction pressure signal function status / alarm
Writing and reading the factory settings on EEprom
EE
WARN.
Low voltage
Table 4: Status and error messages on the main page
The other menu pages vary with the associated functions and are described later by type
of indication or setting. Once you have entered any menu, the bottom of the page always
shows a summary of the main operating parameters (running status or any fault, current
speed and pressure).
This allows a constant view of the machine's fundamental parameters.
Figure 15: Display of a menu parameter
53
Description
Motor running
Motor stopped
Motor status manually disabled
Warning due to lack of supply voltage
Indications on the status bar at the bottom of each page
Identifying code
GO
SB
Disable
rpm
bar
Presence of an error preventing operation of the electropump
FAULT
Table 5: Indications on the status bar
The following may appear on the pages that show parameters: numerical values and units
of measure of the current item, values of other parameters linked to the setting of the current
item, graphic bar, lists; see Figure 15.
4.4 - Blocking parameter setting by Password
The device has a password-enabled protection system. If a password is set, the param-
eters of the device will be accessible and visible but it will not be possible to change them.
The password management system is in the "technical assistance" menu and is managed
by means of the parameter PW.
4.5 - Enabling and disabling the motor
In normal operating conditions, pressing and then releasing both the "˄" and "˅" keys
causes the blocking/release of the motor (self-holding even after switching off). If there is a
fault alarm, the operation described above resets the alarm.
When the motor is disabled this status is shown by the blinking white LED.
This command can be activated from any menu page except RF and PW.
Description
Motor stopped
Motor stopped
Motor status manually disabled
Motor revs per minute
Plant pressure