4
Installatie
Elektrische installatie
4.3.6
Information Regarding UL
Ambient Temperature
Field Wiring Power Terminals
Short Circuit Current Rating
32
Technische handleiding – MOVITRAC
AANWIJZING
Ongeacht de taal van dit document, wordt het volgende hoofdstuk vanwege de UL-
vereisten altijd in het Engels afgedrukt.
The units are suitable for an ambient temperature of 40 °C, max. 60 °C with derated
output current.
To determine output current rating at higher than 40 °C, the output current should be
derated 2.5 % per °C between 40 °C and 50 °C, and 3 % per °C between 50 °C and
60 °C.
Use 60/75 °C copper wire only – Models with suffix 0003 to 0300.
Use 75 °C copper wire only – Models with suffix 0370 to 0750.
Tighten terminals to in-lbs (Nm) as follows:
Series
Frame Size
®
MOVITRAC
0XS, 0S, 0L
1, 2S
2
3
4, 5
Suitable for use on a circuit capable of delivering not more than 200,000 rms sym-
metrical amperes:
®
– MOVITRAC
models with suffix 0003 to 0750 (400 V units only).
Max. voltage is limited to 500 V.
®
– MOVITRAC
models with suffix 0003 to 0300 (230 V units only).
Max. voltage is limited to 240 V.
®
LTE-B+
in-lbs
Nm
4
0.5
5
0.6
13
1.5
31
3.5
120
14

Advertenties