PROBLEM
CAUSE
Empty hopper
Auger blocked by a
foreign object (for
example nails)
Fire
extinguishes
Poor quality pellet
and stove stalls
Pellet loading value too
law "phase 1"
Check if there is an
active alarm "ALAR
DEP", "ALAR SIC")
Running stove
and display
Automatic burning pot
showing "STOP
cleaning
FIRE"
Insufficient combustion
air
Flames are
weak and
Obstructed exhaust
orange, pellets
do not burn
properly and
the glass
Obstructed stove
blackens
Fume aspirator out of
order
Faulty fume temperature
Heat
probe
exchanger fan
keeps turning
even when
the stove has
Faulty electronic board
cooled
FAMILY
SOLUTION
Full the hopper.
Clean the auger.
Try with other types of pellets.
Adjust pellet load.
Have the stove overhauled.
At idling stove and at maximum fume suction NO
PROBLEM!
Check the following inscription: probable obstructions
for combustion air inlet from the stove back or bottom;
obstructed holes of the burning pot grid and/or burning
pot with too ash. Have the fun blades and its screw
cleaned.
The exhaust chimney is partly or fully obstructed.
Contact an expert stove-repairer to check the exhaust
up to the chimney pot. Please clean it immediately.
Clean the stove inner.
Pellet can burn also thank to chimney flue depression
without the aid of the fume fan. Have the fume fan
replaced immediately. It can be harmful to health to
run the stove without fume fan.
Replace the fume probe.
Replace the mother board.
INTERVENTION