PANEL ELEMENT
EN
Display A
Display B
10.4
IGNITION
We remind you that the first ignition must be executed by authorized and skilled technical personnel who checks
that all is installed in compliance with current regulations and verifies stove's efficiency.
• If inside the combustion chamber there are booklets, manuals, etc.... please remove them.
• Check that the door is correctly closed.
• Check that the plug is correctly put into the electric socket.
• Before switching the stove on, please assure you that the burning pot is cleaned.
• To start the stove up, keep pressed P4 key for an instant till the display shows "FAN CAND": the preheating
of the ignition plug starts. After 2 minutes about, the display will show "LOAD WOOD": now the auger load
the pellet and the preheating of the ignition plug continues. When the temperature is suffuciently high (after
about 7-10 minutes), the ignition is considered as occured and the display shows "FIRE ON".
• When the "FIRE ON" phase has finished, the control unit enters in working mode and the selected calorific
power and the ambient temperature will be shown. It is in this phase that P5 and P6 are useful for regulating
the stove power from 1 to 5.
10.5
FLAME REGULATION
If the flame is weak and/or orange coloured, combustion is not perfect. Fumes exhaust speed must be regulated
by an authorized technician.
Changing the type of pellets may make it necessary to regulate the flame again.
10.6
FAILED IGNITION
If the pellets do not burn, the failed ignition will be indicated by the alarm "ALAR NO FIRE"
• If the room temperature is lower than 10°C, the plug is not able to bear the ignition stage. To support it please
insert some pellets in the burning pot and a piece of burning firelighter igniter material on the pellets (for
example firelighters cubes).
18
DESCRIZIONE
Thermostat: activated
Flashing: during the temperature set or when inside the menu
During the starting up shows the mother board state. During the running shows the
heating power. During the setting shows the parameters in modification
During the starting up shows the mother board state. During the working phase shows
the temperature set by the user. During parameters modification shows the value of
the parameter in modification.
Fig. 16 - LED control display
LEGEND
Fig. 16 page 18
1
Display A: state, power (name of the parameter)
2
Display B: state, time, temperature (size value)
FAMILY