• Clean the burning pot and start the stove up again with P4 key.
11.4
"ALAR HOT TEMP" ALARM
EN
If the fume probe find a temperature at the exhaust which is higher than 200°C, the display will show "RIS". At
that point, the combustible flow (pellet) decreases at 1 phase.
This function has the purpose to bring the value back to the preselected data. If for different reasons the
temperature does not decrease but increase, at 215°C the display will show "ALAR HOT TEMP" and the stove
start the switching off phase up.
• The stove starts the switching off phase up by activating the fume fan which for about 15 minutes will arrange
for fume remainings expulsion.
• Reset the error with P4 key.
• Check the type of glitch as provided by ALARMS page 27.
• Clean the burning pot and start the stove up again with P4 key.
11.5
"ALAR NO FIRE" ALARM
• "ALAR NO FIRE": the temperature is not sufficient for ignition.
• The stove starts the switching off phase up by activating the fume fan which for about 15 minutes will arrange
for fume remainings expulsion.
• Reset the error with P4 key.
• Check the type of glitch as provided by ALARMS page 27.
• Clean the burning pot and start the stove up again with P4 key.
11.6
"ALAR DEP" ALARM
To the boiler is connected a pressostat which controls the depression.
• "ALAR DEP": the pressostat stops the power to the auger.
• The stove starts the switching off phase up by activating the fume fan which for about 15 minutes will arrange
for fume remainings expulsion.
• Reset the error with P4 key.
• Check the type of glitch as provided by ALARMS page 27.
• Clean the burning pot and start the stove up again with P4 key.
11.7
"ALAR SIC" ALARM
There is a thermostat probe near the hopper, which cuts in if the temperature range of the hopper exceeds the
limits allowed, thereby eliminating the possibility for the pellets in the hopper to ignite due to overheating.
• "ALAR SIC": the manual reset thermostat cuts out electricity to the auger.
• The stove starts the switching off phase up by activating the fume fan which for about 15 minutes will arrange
for fume remainings expulsion.
• Reset the error with P4 key.
• Check the type of glitch as provided by ALARMS page 27.
• Unscrew the black cap, press the button and screw the cap again.
• Clean the burning pot and start the stove up again with P4 key.
•
12
MAINTEINANCE
12.1
INTRODUCTION
For a long working life of the stove, have a periodic cleaning of the stove as described in the following paragrafs.
• Fume outlet pipes (fume conduit + chimney flue + chimney pot) must always be cleaned, scrubbed and
checked by an authorized technician in compliance with local regulations, with the instructions of the
manufacturer and those of your insurance company.
• If there are no local regulations and no instruction from your insurance company, it is necessary to have your
fume pipe, chimney flue and chimney pot cleaned at least once a year.
• It is also necessary to have the combustion chamber, motors and fans cleaned and to have the gaskets and
the electronical elements checked at least once a year.
22