a possible switching off at lower powers.
• Depending on the type of pellets it could be necessary a parameters adjustment, please contact an
Authorized Assistance Service.
EN
9
INSTALLATION
9.1
INTRODUCTION
• The assembly position must be chosen depending on environment, outlet, chimney flue.
• Check with local authorities if there are any restrictive regulations which regard the combustible air inlet,
room ventilation, fume exhaust system together with chimney flue and chimney pot.
• The manufacturer declines any responsibility in case of installation which are not in compliance with current
regulations, in case of a wrong room ventilation system, in case of an electric connection which is not in
compliance with regulations and in case of a wrong use of the appliance.
• The installation must be executed by an authorized technician, who must release to the user a declaration of
conformity of the system and will assume the whole responsibility on the final installation and on the resulting
good running of the product.
• As equipment with the stove there is a testing and maintenance manual which must be periodically executed
by the installer.
• Check if there is the combustible air inlet.
• Check the probable presence of other stoves or appliances which could depress the room (see EXTERNAL
AIR INLET page 8).
• Check at switched on stove if there is the presence of CO in the room.
• Check if the chimney has the necessary draught.
• Check if during the fume passage all has been executed in safety (probable fume losses and distances from
flammable materials, etc....).
• The installation of the appliance must enable an easy access for appliance, fume exhaust pipes and chimney
flue cleaning.
• The installation must enable en easy access to the electric connection plug (see ELECTRIC CONNECTION
page 15).
• It is forbidden to install the stove in bedrooms, bathrooms and in rooms used for storing combustible materials
and in one-room flats.
• The installation in one-room flats is allowed if they are in sealed chamber.
• In any case the stove must not be installed in rooms where it can get in touch with water or water splashes
because this can cause burn hazards and short-circuit.
• To install more appliances, the external air inlet must be correctly dimensioned (see EXTERNAL AIR INLET page 8).
12