ALARM
CAUSE
EN
Boiler overheating
The ambient exchanger
fan does not work
Temporary black out
ALAR SIC
(when the stove is in
operation)
Faulty thermostat
Faulty mother board
Empty hopper
Burning pot has not been
cleaned
The switching on
threshold to the probe
has not been reached
Faulty ignition plug
ALAR NO FIRE
Too severe external
temperature
Humid pellets
Blocked thermal probe
Faulty mother board
28
SOLUTION
Let stove cool and reset. (If the problem persists, please
contact an Authorized Techinician).
Replace the ambient fan.
The boiler to overheat and requires manual resetting.
Reset and start the stove.
Replace manual reset thermostat.
Replace the electronic board.
Full the hopper.
Clean the burning pot.
Clean the burning pot and switch the stove on again.
(If the problem persists, please contact an Authorized
Techinician).
Replace the igniter resistance.
Start the stove up again.
Check if the pellet is stored in a dry place.
Replace the thermal probe.
Replace the mother board.
INTERVENTION