the burning pot is encrusted and needs to be cleaned. If it is broken, it must be replaced.
EN
12.4
HOPPER AND AUGER CLEANING
Per each pellets supply, check the probable presence of meal, sawdust and other remanins on the hopper
bottom. If present, they must be removed with the aid of a vacuum cleaner (see Fig. 26 page 24).
12.5
FUME CHAMBER CLEANING
Every 4/8 weeks the fume chamber cleaning must be executed.
Fig. 27 - Oven light removing
• Loosen the glass of the oven light (see Fig. 27 page 24).
• Loosen the 8 screws on the oven surround and remove the oven completely (see Fig. 28 page 24).
• Clean with a vacuum cleaner the ash which has accumulated on the inner (see Fig. 29 page 24).
• After the cleaning the opposite operation is to repeat.
24
Fig. 26 - Hopper and auger cleaning
The hand rejector grid must not ever be removed fron its housing. Clean the hopper bottom
and the visible part of the auger exclusively as shown in the picture (see Fig. 26 page 24).
If the auger is blocked by a foreign object (for example: nails), and if it needs to be cleaned,
DO NOT remove the hand rejector and DO NOT touch the auger. Please contact the
Technical Assistance service.
The hand rejector can be removed exclusively by an authorized technician.
Fig. 28 - Unscrew the screws
Fig. 29 - Fume chamber cleaning