9.3
GENERAL INSTALLATION
EN
• Please check that the floor has an adequate load capacity. If the existing one does not satisfy this requirement,
appropriate measure should be provided (for example a plate for distributing the load).
• It is obligatory to install the stove away from walls and/or pieces of furniture, with a minimum air flow of 200
mm on the sides and 200 mm on the back, to enable an eficient appliance cooling and a good distribution
of heat in the room (see Fig. 13 page 14).
• For safety fire regulations the distances from flammable or sensible to heat objects (sofas, pieces of furniture,
wooden covering, etc...) must be respected, has described in Fig. 13 page 14.
• If there are highly flammable objects (curtains, fitted carpet, etc...), all these distances must be further
increased with 1 meter.
• If the walls are made up of flammable materials, check the safety distances (see Fig. 13 page 14).
• At maximum power check that the wall temperature does not ever exceed 80°C. If it would be necessary
please install a fire resistant plate on the concerned walls.
• In some countries also masonring load-bearing walls are considered flammable.
The stove can be inserted between cabinets, with side clearance of 10 mm (see Fig. 14 page 15):
14
Fig. 13 - General installation
LEGEND
Fig. 13 page 14
1
Stove
2
Minimum lateral distance = 200 mm
3
Minimum rear distance = 200 mm
4
Minimum front distance = 800 mm
FAMILY