ALARM
CAUSE
The fire door is not
correctly closed
Obstructed exhaust
Out of order fume fan
Obstructed connecting
nozzle
ALAR DEP
Faulty pressostat
Faulty mother board
Overlength of the
chimney
Adverse wheather
conditions
FAMILY
SOLUTION
Close the fire door correctly and check if the gaskets
are not damaged. (If damaged, have it replaced by an
Authorized Technician)
The exhaust chimney is partially or totally obstructed.
Please contact an expert stove-repairer who checks
the stove from the exhaust till the chimney pot. Have it
immediately cleaned. It can be noxious to health to let
the stove running with an obstructed chimney.
The pellets can burn also due to the chimney flue
depression without the aid of the fume fan. Have the
fume fan replaced immediately. It can be noxoius to
health to let the stove running without fume fan.
Clean the connecting nozzle.
Replace the pressostat.
Replace the mother board.
Contact an expert stove-repairer and check if the
exhaust chimney is in compliance with the regulations:
see CHIMNEY FLUE page 5
In case of strong wind there can be a negative pressure
to the chimney. Check it and switch the stove on again.
INTERVENTION