Parameterlijsten
6.1.9 8-** Comm. and Options
Par.
Parameter description
No. #
8-0* General Settings
8-01
Control Site
8-02
Control Source
8-03
Control Timeout Time
8-04
Control Timeout Function
8-07
Diagnosis Trigger
8-1* Ctrl. Word Settings
8-10
Control Word Pro le
8-14
Con gurable Control Word CTW
8-19
Product Code
8-3* FC Port Settings
8-30
Protocol
8-31
Address
8-32
Baud Rate
8-33
Parity / Stop Bits
8-35
Minimum Response Delay
8-36
Maximum Response Delay
8-37
Maximum Inter-char delay
8-4* FC MC protocol set
8-40
Telegram Selection
8-42
PCD Write Con guration
8-43
PCD Read Con guration
8-5* Digital/Bus
8-50
Coasting Select
8-51
Quick Stop Select
8-52
DC Brake Select
8-53
Start Select
8-54
Reversing Select
8-55
Set-up Select
8-56
Preset Reference Select
8-57
Pro drive OFF2 Select
8-58
Pro drive OFF3 Select
8-7* BACnet
8-70
BACnet Device Instance
8-72
MS/TP Max Masters
8-73
MS/TP Max Info Frames
8-74
"I am" Service
8-75
Intialisation Password
8-79
Protocol Firmware version
8-8* FC Port Diagnostics
8-80
Bus Message Count
8-81
Bus Error Count
8-82
Slave Messages Rcvd
8-83
Slave Error Count
8-84
Slave Messages Sent
8-85
Slave Timeout Errors
8-88
Reset FC port Diagnostics
8-9* Bus Jog / Feedback
8-90
Bus Jog 1 Speed
8-91
Bus Jog 2 Speed
MG03N210
Programmeerhandleiding
Default value
[0] Digital and ctrl.word
All set-ups
ExpressionLimit
All set-ups
1 s
[0] O
[0] Disable
[0] FC pro le
All set-ups
[1] Pro le default
All set-ups
ExpressionLimit
[0] FC
1 N/A
ExpressionLimit
ExpressionLimit
0.01 s
ExpressionLimit
0.025 s
[1] Standard telegram 1
2 set-ups
ExpressionLimit
2 set-ups
ExpressionLimit
[3] Logic OR
All set-ups
[3] Logic OR
All set-ups
[3] Logic OR
All set-ups
[3] Logic OR
All set-ups
[0] Digital input
All set-ups
[3] Logic OR
All set-ups
[3] Logic OR
All set-ups
[3] Logic OR
All set-ups
[3] Logic OR
All set-ups
1 N/A
127 N/A
1 N/A
[0] Send at power-up
[admin]
ExpressionLimit
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
[0] Do not reset
100 RPM
All set-ups
200 RPM
All set-ups
Danfoss A/S © 11/2015 Alle rechten voorbehouden.
4-set-up
Change during
operation
TRUE
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
TRUE
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
TRUE
TRUE
1 set-up
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
FALSE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
TRUE
TRUE
Conversion
Type
index
-
Uint8
-
Uint8
-1
Uint16
-
Uint8
-
Uint8
-
Uint8
-
Uint8
0
Uint32
6
-
Uint8
0
Uint8
-
Uint8
-
Uint8
-3
Uint16
-3
Uint16
-3
Uint16
-
Uint8
-
Uint8
-
uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
0
Uint32
0
Uint8
0
Uint16
-
Uint8
0
VisStr[20]
-2
Uint16
0
Uint32
0
Uint32
0
Uint32
0
Uint32
0
Uint32
0
Uint32
-
Uint8
67
Uint16
67
Uint16
143
6